Rankiteo Logo
Rankiteo
Leader in Cyber Underwriting
Loading...
NEWRankiteo Cyber Underwriting Desktop - Score, price, and bind from your desktop
WindowsmacOSLinux
Download

Comparison Overview

Trauson Medical InstrumentsTrauson Medical Instruments
VS
STERISSTERIS
Trauson Medical Instruments

Trauson Medical Instruments

Changzhou, CN

Last Update: 04/04/2026

View Profile
Between 750 and 799
https://www.trauson.com
760/1000Fair

Trauson, as a Stryker branch company, is located in Wujing High-tech Industrial Zone, Changzhou, Jiangsu. Trauson was established in 1986, is one of the pioneering enterprises in China’s orthopaedic industry, and one of the leading manufacturers of trauma products and ...

NAICS:3391
NAICS Definition:Medical Equipment and Supplies Manufacturing
Employees:167
Subsidiaries:39
12-month incidents
0
Known data breaches
0
Attack type number
0
STERIS

STERIS

5960 Heisley Rd, Mentor, 44060, US

Last Update: 01/04/2026

View Profile
Between 750 and 799
https://www.steris.com
781/1000Fair

STERIS is a leading provider of infection prevention and other procedural products and services, focused primarily on healthcare, pharmaceutical and medical device Customers. MISSION WE HELP OUR CUSTOMERS CREATE A HEALTHIER AND SAFER WORLD by providing innovative healt...

NAICS:3391
NAICS Definition:Medical Equipment and Supplies Manufacturing
Employees:10,716
Subsidiaries:9
12-month incidents
0
Known data breaches
0
Attack type number
0

Compliance Ranges Comparison

Based On Specific Ai Models Category
Trauson Medical Instruments

Trauson Medical Instruments

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA
STERIS

STERIS

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA

Benchmark & Cyber Underwriting Signals

Incidents vs Medical Equipment Manufacturing Industry Avg (This Year)

No incidents recorded for Trauson Medical Instruments in 2026.

Incidents

Incidents vs Medical Equipment Manufacturing Industry Avg (This Year)

No incidents recorded for STERIS in 2026.

Incidents

Incident History - Trauson Medical Instruments (X = Date, Y = Severity)

Trauson Medical Instruments cyber incidents detection timeline including parent company and subsidiaries.

R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Incident History - STERIS (X = Date, Y = Severity)

STERIS cyber incidents detection timeline including parent company and subsidiaries.

No timeline data available
R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Notable Incidents

Last Cyber / HR Incidents / Global...
Trauson Medical Instruments

Trauson Medical Instruments

Incidents
No explicit notable incidents reported.
STERIS

STERIS

Incidents
No explicit notable incidents reported.

FAQ

Between Trauson Medical Instruments company and STERIS company, which one has the best AI Cybersecurity Score ?
Between Trauson Medical Instruments company and STERIS company, which one has experienced more cyber incidents in the past ?
Between Trauson Medical Instruments company and STERIS company, which one has experienced more cyber incidents this year ?
Between Trauson Medical Instruments company and STERIS company, which one has experienced at least one ransomware attack ?
Between Trauson Medical Instruments company and STERIS company, which one has experienced at least one data breach ?
Between Trauson Medical Instruments company and STERIS company, which one has experienced at least one targeted cyberattack ?
Between Trauson Medical Instruments company and STERIS company, which one has experienced at least one vulnerability ?
Between Trauson Medical Instruments company and STERIS company, which one holds the most compliance certifications ?
Between Trauson Medical Instruments company and STERIS company, which one holds the fewest compliance certifications ?
Between Trauson Medical Instruments company and STERIS company, which one has the most subsidiaries ?
Between Trauson Medical Instruments company and STERIS company, which one has the largest number of employees ?
Between Trauson Medical Instruments and STERIS, which company holds both SOC 2 Type 1 certifications ?
Between Trauson Medical Instruments and STERIS, which company holds both SOC 2 Type 2 certifications ?
Which company is ISO 27001 certified - Trauson Medical Instruments or STERIS ?
Which company is PCI DSS compliant - Trauson Medical Instruments or STERIS ?
Between Trauson Medical Instruments and STERIS, which company complies with HIPAA regulations for healthcare data ?
Between Trauson Medical Instruments and STERIS, which company complies with GDPR requirements ?

Latest Global CVEs

CVE-2026-19961
SUMMARY

A vulnerability was detected in Edimax EW-7478APC 1.04. Affected is the function formWlSiteSurvey of the file /goform/formWlSiteSurvey. Performing a manipulation of the argument selSSID results in buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

PUBLISHED
Date2026-08-16
UPDATED
Date2026-08-16
RISK INFORMATION (Score: 9.9)
CVSS2
Base Score: 9.0
Complexity: LOW
AV:N/AC:L/Au:S/C:C/I:C/A:C
CVSS3
Base Score: 9.9
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
CVSS4
Base Score: 8.6
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
6
EXPLOITABILITY
3.1
CVE-2026-19960
SUMMARY

A security vulnerability has been detected in Edimax EW-7478APC 1.04. This impacts the function formWlbasic of the file /goform/formWlbasic. Such manipulation of the argument rootAPmac leads to command injection. The attack can be executed remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

PUBLISHED
Date2026-08-16
UPDATED
Date2026-08-16
RISK INFORMATION (Score: 7.4)
CVSS2
Base Score: 6.5
Complexity: LOW
AV:N/AC:L/Au:S/C:P/I:P/A:P
CVSS3
Base Score: 7.4
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L
CVSS4
Base Score: 2.1
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
3.7
EXPLOITABILITY
3.1
CVE-2026-19959
SUMMARY

A weakness has been identified in Edimax EW-7478APC 1.04. This affects the function formWanTcpipSetup of the file /goform/formWanTcpipSetup. This manipulation of the argument pppUserName causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.

PUBLISHED
Date2026-08-16
UPDATED
Date2026-08-16
RISK INFORMATION (Score: 9.9)
CVSS2
Base Score: 9.0
Complexity: LOW
AV:N/AC:L/Au:S/C:C/I:C/A:C
CVSS3
Base Score: 9.9
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
CVSS4
Base Score: 8.6
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
6
EXPLOITABILITY
3.1
CVE-2026-19958
SUMMARY

A security flaw has been discovered in iatsiuk pptr-mcp up to 0.2.7. The impacted element is the function executeCode of the file src/vm-executor.ts of the component execute Tool. The manipulation results in code injection. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks. The project was informed of the problem early through an issue report but has not responded yet.

PUBLISHED
Date2026-08-16
UPDATED
Date2026-08-16
RISK INFORMATION (Score: 6.3)
CVSS2
Base Score: 6.5
Complexity: LOW
AV:N/AC:L/Au:S/C:P/I:P/A:P
CVSS3
Base Score: 6.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CVSS4
Base Score: 2.1
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
3.4
EXPLOITABILITY
2.8
CVE-2026-19957
SUMMARY

A vulnerability was identified in graphlit graphlit-mcp-server 1.0.1. This affects the function fetch of the file src/tools.ts of the component ssrf-test Endpoint. Such manipulation of the argument url leads to server-side request forgery. The attack may be launched remotely. The exploit is publicly available and might be used. The project was informed of the problem early through an issue report but has not responded yet.

PUBLISHED
Date2026-08-16
UPDATED
Date2026-08-16
RISK INFORMATION (Score: 6.3)
CVSS2
Base Score: 6.5
Complexity: LOW
AV:N/AC:L/Au:S/C:P/I:P/A:P
CVSS3
Base Score: 6.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CVSS4
Base Score: 2.1
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
3.4
EXPLOITABILITY
2.8