Rankiteo Logo
Rankiteo
Leader in Cyber Underwriting
Loading...
NEWRankiteo Cyber Underwriting Desktop - Score, price, and bind from your desktop
WindowsmacOSLinux
Download

Comparison Overview

Tower SemiconductorTower Semiconductor
VS
Texas InstrumentsTexas Instruments
Tower Semiconductor

Tower Semiconductor

Ramat Gavriel Industrial Area, Migdal Haemek, 23105, IL

Last Update: 04/04/2026

View Profile
Between 750 and 799
http://www.towersemi.com
795/1000Fair

Tower Semiconductor (www.towersemi.com), the leading foundry of high-value analog semiconductor solutions, specializes in manufacturing analog ICs for more than 300 customers worldwide in growing markets such as communication, automotive, medical, industrial, consumer, ...

NAICS:3344
NAICS Definition:Semiconductor and Other Electronic Component Manufacturing
Employees:1,461
Subsidiaries:0
12-month incidents
0
Known data breaches
0
Attack type number
1
Texas Instruments

Texas Instruments

12500 T I Blvd, Dallas, 75243, US

Last Update: 02/04/2026

View Profile
Between 800 and 849
http://www.ti.com
832/1000Good

We are a global semiconductor company that designs, manufactures and sells analog and embedded processing chips for markets such as industrial, automotive, personal electronics, enterprise systems and communications equipment. At our core, we have a passion to create a ...

NAICS:3344
NAICS Definition:Semiconductor and Other Electronic Component Manufacturing
Employees:32,501
Subsidiaries:1
12-month incidents
0
Known data breaches
0
Attack type number
0

Compliance Ranges Comparison

Based On Specific Ai Models Category
Tower Semiconductor

Tower Semiconductor

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA
Texas Instruments

Texas Instruments

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA

Benchmark & Cyber Underwriting Signals

Incidents vs Semiconductor Manufacturing Industry Avg (This Year)

No incidents recorded for Tower Semiconductor in 2026.

Incidents

Incidents vs Semiconductor Manufacturing Industry Avg (This Year)

No incidents recorded for Texas Instruments in 2026.

Incidents

Incident History - Tower Semiconductor (X = Date, Y = Severity)

Tower Semiconductor cyber incidents detection timeline including parent company and subsidiaries.

R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Incident History - Texas Instruments (X = Date, Y = Severity)

Texas Instruments cyber incidents detection timeline including parent company and subsidiaries.

No timeline data available
R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Notable Incidents

Last Cyber / HR Incidents / Global...
Tower Semiconductor

Tower Semiconductor

Incidents
🔒 Incident : Cyber Attack
TOW64518623
Texas Instruments

Texas Instruments

Incidents
No explicit notable incidents reported.

FAQ

Between Tower Semiconductor company and Texas Instruments company, which one has the best AI Cybersecurity Score ?
Between Tower Semiconductor company and Texas Instruments company, which one has experienced more cyber incidents in the past ?
Between Tower Semiconductor company and Texas Instruments company, which one has experienced more cyber incidents this year ?
Between Tower Semiconductor company and Texas Instruments company, which one has experienced at least one ransomware attack ?
Between Tower Semiconductor company and Texas Instruments company, which one has experienced at least one data breach ?
Between Tower Semiconductor company and Texas Instruments company, which one has experienced at least one targeted cyberattack ?
Between Tower Semiconductor company and Texas Instruments company, which one has experienced at least one vulnerability ?
Between Tower Semiconductor company and Texas Instruments company, which one holds the most compliance certifications ?
Between Tower Semiconductor company and Texas Instruments company, which one holds the fewest compliance certifications ?
Between Tower Semiconductor company and Texas Instruments company, which one has the most subsidiaries ?
Between Tower Semiconductor company and Texas Instruments company, which one has the largest number of employees ?
Between Tower Semiconductor and Texas Instruments, which company holds both SOC 2 Type 1 certifications ?
Between Tower Semiconductor and Texas Instruments, which company holds both SOC 2 Type 2 certifications ?
Which company is ISO 27001 certified - Tower Semiconductor or Texas Instruments ?
Which company is PCI DSS compliant - Tower Semiconductor or Texas Instruments ?
Between Tower Semiconductor and Texas Instruments, which company complies with HIPAA regulations for healthcare data ?
Between Tower Semiconductor and Texas Instruments, which company complies with GDPR requirements ?

Latest Global CVEs

CVE-2026-56785
SUMMARY

FlatPress versions prior to commit 10be83c, contains a stored cross-site scripting vulnerability in comment and contact forms where name, URL, and email fields are rendered without proper output encoding in Smarty templates. Attackers can inject arbitrary HTML and JavaScript through these fields to execute malicious scripts in browsers of viewers including administrators, or bypass URL scheme validation to inject javascript: or data: URIs.

PUBLISHED
Date2026-06-23
UPDATED
Date2026-06-23
RISK INFORMATION (Score: 8.2)
CVSS3
Base Score: 8.2
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N
CVSS4
Base Score: 8.4
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:L/VA:N/SC:H/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
4.7
EXPLOITABILITY
2.8
CVE-2026-54588
SUMMARY

Poweradmin is a web-based DNS administration tool for PowerDNS server. Versions prior to 4.2.4 and 4.3.3 use the attacker-controlled `HTTP_HOST` request header as the authoritative source for building callback URLs in its OIDC, SAML, and logout authentication flows without any validation. An unauthenticated attacker can poison the `redirect_uri` sent to the Identity Provider, causing the IdP to redirect the victim's authorization code to an attacker-controlled server - resulting in full account takeover with no credentials required. Versions 4.2.4 and 4.3.3 patch the issue.

PUBLISHED
Date2026-06-23
UPDATED
Date2026-06-23
RISK INFORMATION (Score: 9.6)
CVSS3
Base Score: 9.6
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:L
IMPACT SCORE
6
EXPLOITABILITY
2.8
CVE-2026-48493
SUMMARY

Snipe-IT is an IT asset/license management system. In versions prior to 8.6.0, a user with only users.edit can send a PATCH to /api/v1/users/{their_own_id} and grant themselves any permission except admin and superuser — for example `assets.view`, `assets.create`, `reports.view`, import, etc. The issue is patched in version 8.6.0.

PUBLISHED
Date2026-06-23
UPDATED
Date2026-06-23
RISK INFORMATION (Score: 5.5)
CVSS3
Base Score: 5.5
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:H/A:N
IMPACT SCORE
4.2
EXPLOITABILITY
1.2
CVE-2026-47693
SUMMARY

Poweradmin is a web-based DNS administration tool for PowerDNS server. Versions prior to 4.2.4 and 4.3.3 are vulnerable to CSV Injection (Formula Injection) in its log export functionality. User-controlled data — specifically the username field — is written to exported CSV files without sanitizing formula trigger characters (=, +, -, @). When an administrator exports activity logs and opens the resulting CSV in a spreadsheet application (Microsoft Excel, LibreOffice Calc, Google Sheets), any formula stored in a username is executed by the application. This can be used for phishing attacks against administrators or data exfiltration. Versions 4.2.4 and 4.3.3 patch the issue.

PUBLISHED
Date2026-06-23
UPDATED
Date2026-06-23
RISK INFORMATION (Score: 6.9)
CVSS3
Base Score: 6.9
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:L/A:N
IMPACT SCORE
4.7
EXPLOITABILITY
1.7
CVE-2026-12164
SUMMARY

Fortra File Integrity Monitoring (FIM), formerly Tripwire Enterprise, versions prior to 9.4.0 may assign incorrect or elevated effective permissions to users created by the tetool import command while FIM is running, particularly when the import also creates or changes roles or role-permission relationships.

PUBLISHED
Date2026-06-23
UPDATED
Date2026-06-23
RISK INFORMATION (Score: 4.4)
CVSS3
Base Score: 4.4
Complexity: LOW
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N
IMPACT SCORE
3.6
EXPLOITABILITY
0.8