Comparison Overview
Teladoc Health UK

Teladoc Health UK
Aspect House, Brighton, East Sussex, BN1 3XE, GB
Last Update: 03/02/2026
The world's leading Virtual Healthcare provider. From 24/7 virtual GPs, physiotherapy, second medical opinion, nutrition, and mental health support - we deliver excellent clinical outcomes - 96% of users recommend us. Teladoc Health UK leverages more than 20 years of e...

BrightSpring Health Services
805 N Whittington Pkwy, Louisville, 40222, US
Last Update: 30/03/2026
BrightSpring is the parent company of a family of services and brands that provides clinical, nonclinical, pharmacy and ancillary care services for people of all ages, health and skill levels across home and community settings. The company is a leading provider of div...
Compliance Ranges Comparison

Teladoc Health UK







BrightSpring Health Services






Benchmark & Cyber Underwriting Signals
Incidents vs Hospitals and Health Care Industry Avg (This Year)
No incidents recorded for Teladoc Health UK in 2026.
Incidents vs Hospitals and Health Care Industry Avg (This Year)
No incidents recorded for BrightSpring Health Services in 2026.
Incident History - Teladoc Health UK (X = Date, Y = Severity)
Teladoc Health UK cyber incidents detection timeline including parent company and subsidiaries.
Incident History - BrightSpring Health Services (X = Date, Y = Severity)
BrightSpring Health Services cyber incidents detection timeline including parent company and subsidiaries.
Notable Incidents

Teladoc Health UK

BrightSpring Health Services
FAQ
Latest Global CVEs
In OpenStack Designate before 22.0.2, the mDNS handler performs pool-blind lookups when resolving record queries and NOTIFY requests. When two zones with the same name exist across different pools, the lookup fails with a deterministic error, causing the handler to return REFUSED for all DNS queries through that path. The _handle_notify path is exploitable via a single unauthenticated UDP packet. This is independently reachable through the cross-tenant zone overlap described in a different recent CVE, and also affects legitimate same-tenant cross-pool configurations. BIND9 views do not mitigate this issue as mDNS is a shared service upstream of any view configuration.
In OpenStack Designate before 22.0.1, zone creation checks (_is_subzone, _is_superzone, and the duplicate-zone DB constraint) are scoped to the target pool only. An authenticated user can bypass these checks by scheduling a zone to a different pool via the AttributeFilter scheduler, creating an overlapping zone that conflicts with another tenant's zone. This enables cross-tenant DNS hijack (redirecting traffic to attacker-controlled IPs) and DNS denial of service (NODATA responses). Exploitation requires a multi-pool deployment with AttributeFilter enabled in scheduler_filters, which is a non-default but documented and supported configuration for self-service tiering.
UpSnap is a wake on lan web app. Versions prior to 5.4.0 have an OS command injection vulnerability in the UpSnap’s device management functionality due to the presence of unsafe shell command template interpolation using the ip and the mac fields. User-controlled values can be inserted into the wake_cmd and shutdown_cmd templates and executed via /bin/sh -c (Linux) or cmd /C (Windows) without sanitization, resulting in an authenticated Remote Code Execution (RCE). A low-privileged user with permission to create or edit devices can execute arbitrary operating system commands on the UpSnap hosted server. Version 5.4.0 patches the issue.
FUXA is a web-based Process Visualization (SCADA/HMI/Dashboard) software. When `secureEnabled=true`, FUXA `1.3.0-2773` still allows guest and invalid-token requests to read project, alarms, and scheduler APIs. Version 1.3.1 fixes this issue.
FUXA is a web-based Process Visualization (SCADA/HMI/Dashboard) software. In fuxa-server version 1.3.0, the GET /api/project endpoint exposes sensitive project configuration data to guest-context requests even when secureEnabled is enabled. Version 1.3.1 fixes the issue.