Rankiteo Logo
Rankiteo
Leader in Cyber Underwriting
Loading...
NEWRankiteo Cyber Underwriting Desktop - Score, price, and bind from your desktop
WindowsmacOSLinux
Download

Comparison Overview

SunoSuno
VS
ProsusProsus
Suno

Suno

Cambridge, US

Last Update: 28/07/2026

View Profile
Between 0 and 549
https://suno.com/
449/1000Critical

Suno is building a future where anyone can make music. Whether you're a shower singer or a charting artist, we break barriers between you and the song you dream of making. No instrument needed, just imagination. From your mind to music.

NAICS:513
NAICS Definition:Others
Employees:443
Subsidiaries:0
12-month incidents
2
Known data breaches
3
Attack type number
2
Prosus

Prosus

Gustav Mahlerplein 5, Amsterdam, North Holland, NL, 1082MS

Last Update: 21/09/2026

View Profile
Between 750 and 799
https://prosus.com
789/1000Fair

Prosus is the power behind the world’s leading lifestyle e-commerce brands. Bringing together bold ideas and the power of AI, Prosus builds technology ecosystems where lifestyle ecommerce brands can become global success stories. These ecosystems span three core geogra...

NAICS:513
NAICS Definition:Others
Employees:11,329
Subsidiaries:19
12-month incidents
0
Known data breaches
0
Attack type number
0

Compliance Ranges Comparison

Based On Specific Ai Models Category
Suno

Suno

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA
Prosus

Prosus

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA

Benchmark & Cyber Underwriting Signals

Incidents vs Technology, Information and Internet Industry Avg (This Year)

Suno has 24.22% more incidents than the average of same-industry companies with at least one recorded incident.

Incidents

Incidents vs Technology, Information and Internet Industry Avg (This Year)

No incidents recorded for Prosus in 2026.

Incidents

Incident History - Suno (X = Date, Y = Severity)

Suno cyber incidents detection timeline including parent company and subsidiaries.

R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Incident History - Prosus (X = Date, Y = Severity)

Prosus cyber incidents detection timeline including parent company and subsidiaries.

No timeline data available
R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Notable Incidents

Last Cyber / HR Incidents / Global...
Suno

Suno

Incidents
🔒 Incident : Cyber Attack
DEESUNGEN1784831487
🔒 Incident : Breach
STRSUN1784651361
🔒 Incident : Breach
GENSTRBRISUN1784666335
Prosus

Prosus

Incidents
No explicit notable incidents reported.

FAQ

Between Suno company and Prosus company, which one has the best AI Cybersecurity Score ?
Between Suno company and Prosus company, which one has experienced more cyber incidents in the past ?
Between Suno company and Prosus company, which one has experienced more cyber incidents this year ?
Between Suno company and Prosus company, which one has experienced at least one ransomware attack ?
Between Suno company and Prosus company, which one has experienced at least one data breach ?
Between Suno company and Prosus company, which one has experienced at least one targeted cyberattack ?
Between Suno company and Prosus company, which one has experienced at least one vulnerability ?
Between Suno company and Prosus company, which one holds the most compliance certifications ?
Between Suno company and Prosus company, which one holds the fewest compliance certifications ?
Between Suno company and Prosus company, which one has the most subsidiaries ?
Between Suno company and Prosus company, which one has the largest number of employees ?
Between Suno and Prosus, which company holds both SOC 2 Type 1 certifications ?
Between Suno and Prosus, which company holds both SOC 2 Type 2 certifications ?
Which company is ISO 27001 certified - Suno or Prosus ?
Which company is PCI DSS compliant - Suno or Prosus ?
Between Suno and Prosus, which company complies with HIPAA regulations for healthcare data ?
Between Suno and Prosus, which company complies with GDPR requirements ?

Latest Global CVEs

CVE-2026-94426
SUMMARY

A vulnerability was determined in xuxueli xxl-job up to 3.5.0. The impacted element is an unknown function of the file /jobgroup/insert. This manipulation of the argument Name causes cross site scripting. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.

PUBLISHED
Date2026-09-21
UPDATED
Date2026-09-21
RISK INFORMATION (Score: 3.5)
CVSS2
Base Score: 4.0
Complexity: LOW
AV:N/AC:L/Au:S/C:N/I:P/A:N
CVSS3
Base Score: 3.5
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N
CVSS4
Base Score: 2.0
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
1.4
EXPLOITABILITY
2.1
CVE-2026-94425
SUMMARY

A vulnerability was found in Moore Threads MTT S80 Driver Package 340.150. The affected element is the function sub_140006F0C in the library mtdispkm64.sys of the component IOCTL Handler. The manipulation results in improper privilege management. Attacking locally is a requirement. The vendor was contacted early about this disclosure but did not respond in any way.

PUBLISHED
Date2026-09-21
UPDATED
Date2026-09-21
RISK INFORMATION (Score: 8.8)
CVSS2
Base Score: 6.8
Complexity: LOW
AV:L/AC:L/Au:S/C:C/I:C/A:C
CVSS3
Base Score: 8.8
Complexity: LOW
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
CVSS4
Base Score: 9.3
Complexity: LOW
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
6
EXPLOITABILITY
2
CVE-2026-94627
SUMMARY

vLLM Mooncake connector through 0.29.0 fails to properly manage GPU KV cache block ownership when concurrent child requests share a single transfer ID in prefill/decode disaggregated deployments. Attackers can trigger GPU memory exhaustion by submitting completion requests with multiple prompts, causing orphaned KV cache blocks to accumulate until process restart and eventually preventing legitimate requests from executing.

PUBLISHED
Date2026-09-21
UPDATED
Date2026-09-21
RISK INFORMATION (Score: 7.5)
CVSS3
Base Score: 7.5
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CVSS4
Base Score: 8.7
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
3.6
EXPLOITABILITY
3.9
CVE-2026-94626
SUMMARY

vLLM through 0.29.0 fails to validate the tp_size parameter in kv_transfer_params on OpenAI-compatible completion endpoints, allowing attackers to allocate unbounded memory. Attackers can supply arbitrary tp_size values in prefill/decode disaggregated deployments to exhaust memory and trigger kernel OOM-kill of the decode worker process.

PUBLISHED
Date2026-09-21
UPDATED
Date2026-09-21
RISK INFORMATION (Score: 7.5)
CVSS3
Base Score: 7.5
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CVSS4
Base Score: 8.7
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
3.6
EXPLOITABILITY
3.9
CVE-2026-94625
SUMMARY

vLLM through 0.29.0 contains a resource exhaustion vulnerability in MooncakeConnector where rejected prefill requests create ownerless transfer placeholders that are never reclaimed. Attackers can send rejected requests to exhaust sender task pools, causing valid requests to be delayed by up to 480 seconds while health checks continue returning success.

PUBLISHED
Date2026-09-21
UPDATED
Date2026-09-21
RISK INFORMATION (Score: 5.3)
CVSS3
Base Score: 5.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
CVSS4
Base Score: 6.9
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
1.4
EXPLOITABILITY
3.9