Comparison Overview
SmartestEnergy

SmartestEnergy
The Columbus Building, London, E14 4HD, GB
Last Update: 08/12/2025
SmartestEnergy is a people-powered energy company, empowering switched on customers, generators and partners to get to net zero. We know the journey to 100% renewable energy is complex, because everyone’s at different stages with unique needs. That’s why our model is fl...

Dubai Electricity & Water Authority - DEWA
Sheikh Rashid Road, Umm Hureir2, Umm Hureir, Dubai. Makani Number: 31079 91073, Dubai, Dubai, AE, 564
Last Update: 03/09/2026
Dubai Electricity and Water Authority (DEWA), established on 1 January 1992, stands at the forefront of sustainable energy and water management. With a dedicated workforce of over 11,000 employees, we ensure reliable services across the entire chain of electricity and w...
Compliance Ranges Comparison

SmartestEnergy







Dubai Electricity & Water Authority - DEWA






Benchmark & Cyber Underwriting Signals
Incidents vs Utilities Industry Avg (This Year)
No incidents recorded for SmartestEnergy in 2026.
Incidents vs Utilities Industry Avg (This Year)
No incidents recorded for Dubai Electricity & Water Authority - DEWA in 2026.
Incident History - SmartestEnergy (X = Date, Y = Severity)
SmartestEnergy cyber incidents detection timeline including parent company and subsidiaries.
Incident History - Dubai Electricity & Water Authority - DEWA (X = Date, Y = Severity)
Dubai Electricity & Water Authority - DEWA cyber incidents detection timeline including parent company and subsidiaries.
Notable Incidents

SmartestEnergy

Dubai Electricity & Water Authority - DEWA
FAQ
Latest Global CVEs
MOOS-IvP through 24.8.1 fails to properly validate variable names extracted from alog files in the SplitHandler, allowing attackers to write files outside the split directory. Attackers can supply crafted alog files with backslash sequences in variable names to escape the output directory and append to arbitrary files on Windows systems.
- https://github.com/moos-ivp/moos-ivp
- https://github.com/moos-ivp/moos-ivp/blob/1de9ae146cd63c209e8c3fd81611a4ed2472971b/ivp/src/lib_logutils/SplitHandler.cpp#L189
- https://github.com/moos-ivp/moos-ivp/commit/6f0619e905b325d6b88f76425673045c6e4f6f94
- https://github.com/moos-ivp/moos-ivp/pull/137
- https://www.vulncheck.com/advisories/moos-ivp-through-24.8.1-alog-splitting-path-traversal-on-windows
MOOS core-moos through 10.4.0 contains a buffer over-read vulnerability in CMOOSCommPkt where a four-byte packet triggers out-of-bounds memory access during deserialization. Attackers can open a TCP connection to the MOOSDB port and send a crafted short packet to read memory before authentication.
- https://github.com/themoos/core-moos
- https://github.com/themoos/core-moos/blob/ec9c77c68fcbdef8f5e4c60fe243acd223433f0c/Core/libMOOS/Comms/MOOSCommPkt.cpp#L228
- https://github.com/themoos/core-moos/commit/d30c14585753f9ae39749d9628ed15c8383f0568
- https://github.com/themoos/core-moos/pull/75
- https://www.vulncheck.com/advisories/moos-core-moos-through-10.4.0-moosdb-out-of-bounds-read-via-short-packet
MOOS core-moos through 10.4.0 contains a buffer overflow vulnerability in CMOOSSerialPort::GetTelegram() that writes a NUL terminator one byte past the serial telegram stack buffer. Attackers controlling the serial line can send a full-length telegram to trigger the off-by-one write, corrupting the stack and potentially enabling code execution.
- https://github.com/themoos/core-moos
- https://github.com/themoos/core-moos/blob/ec9c77c68fcbdef8f5e4c60fe243acd223433f0c/Core/libMOOS/Utils/MOOSSerialPort.cpp#L595
- https://github.com/themoos/core-moos/commit/befb04df2039d0080715ea35f56268092db4ec0f
- https://github.com/themoos/core-moos/pull/73
- https://www.vulncheck.com/advisories/moos-core-moos-through-10.4.0-off-by-one-buffer-overflow-in-serial-telegram-handling
MOOS core-moos through 10.4.0 fails to escape database contents when rendering MOOSDB HTTP pages, allowing attackers to inject malicious scripts. Any MOOS publisher can set variable values containing script payloads that execute in the browser of operators viewing the web interface.
- https://github.com/themoos/core-moos
- https://github.com/themoos/core-moos/blob/ec9c77c68fcbdef8f5e4c60fe243acd223433f0c/Core/libMOOS/DB/HTTPConnection.cpp#L460
- https://github.com/themoos/core-moos/commit/a3f26f099bb08decb143f704d8b1ca16ae405b44
- https://github.com/themoos/core-moos/pull/78
- https://www.vulncheck.com/advisories/moos-core-moos-through-10.4.0-moosdb-http-pages-stored-cross-site-scripting
MOOS ui-moos through 50b9c6c contains a buffer overflow vulnerability in ScopeTabPane.cpp and ScopeGrid.cpp where client and variable names are formatted into fixed 1024-byte buffers using sprintf without length validation. Attackers can supply arbitrarily long MOOS identifiers that overflow the buffers when an operator selects process list entries or pokes variables, enabling code execution.
- https://github.com/themoos/ui-moos
- https://github.com/themoos/ui-moos/blob/50b9c6c65169c501f746cfef1e167f74a7735e74/Tools/Graphical/uMS/ScopeTabPane.cpp#L243
- https://github.com/themoos/ui-moos/commit/a6ebc0bc6cb360315ce620e865f996d189cddb0e
- https://github.com/themoos/ui-moos/pull/5
- https://www.vulncheck.com/advisories/moos-ui-moos-through-50b9c6c-ums-buffer-overflow-via-long-moos-identifiers