Rankiteo Logo
Rankiteo
Leader in Cyber Underwriting
Loading...
NEWRankiteo Cyber Underwriting Desktop - Score, price, and bind from your desktop
WindowsmacOSLinux
Download

Comparison Overview

Phonak USPhonak US
VS
MedlineMedline
Phonak US

Phonak US

Aurora, US

Last Update: 27/02/2026

View Profile
Between 750 and 799
https://www.phonak.com/en-us
761/1000Fair

Based outside of Chicago, Illinois, Phonak US has a rich history in innovating hearing technology and solutions. As a member of the Sonova group, our international headquarters are near Zurich, Switzerland. Phonak was born in 1947 from a passion and dedication to take o...

NAICS:3391
NAICS Definition:Medical Equipment and Supplies Manufacturing
Employees:None
Subsidiaries:21
12-month incidents
0
Known data breaches
0
Attack type number
0
Medline

Medline

Three Lakes Drive, Northfield, IL, US, 60093

Last Update: 01/04/2026

View Profile
Between 750 and 799
http://www.medline.com
793/1000Fair

Medline is the largest provider of medical-surgical products and supply chain solutions serving all points of care. Through its unique offering of world-class products, supply chain resilience and clinical practice expertise, Medline delivers improved clinical, financia...

NAICS:3391
NAICS Definition:Medical Equipment and Supplies Manufacturing
Employees:17,899
Subsidiaries:10
12-month incidents
0
Known data breaches
0
Attack type number
0

Compliance Ranges Comparison

Based On Specific Ai Models Category
Phonak US

Phonak US

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA
Medline

Medline

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA

Benchmark & Cyber Underwriting Signals

Incidents vs Medical Equipment Manufacturing Industry Avg (This Year)

No incidents recorded for Phonak US in 2026.

Incidents

Incidents vs Medical Equipment Manufacturing Industry Avg (This Year)

No incidents recorded for Medline in 2026.

Incidents

Incident History - Phonak US (X = Date, Y = Severity)

Phonak US cyber incidents detection timeline including parent company and subsidiaries.

No timeline data available
R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Incident History - Medline (X = Date, Y = Severity)

Medline cyber incidents detection timeline including parent company and subsidiaries.

No timeline data available
R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Notable Incidents

Last Cyber / HR Incidents / Global...
Phonak US

Phonak US

Incidents
No explicit notable incidents reported.
Medline

Medline

Incidents
No explicit notable incidents reported.

FAQ

Between Phonak US company and Medline company, which one has the best AI Cybersecurity Score ?
Between Phonak US company and Medline company, which one has experienced more cyber incidents in the past ?
Between Phonak US company and Medline company, which one has experienced more cyber incidents this year ?
Between Phonak US company and Medline company, which one has experienced at least one ransomware attack ?
Between Phonak US company and Medline company, which one has experienced at least one data breach ?
Between Phonak US company and Medline company, which one has experienced at least one targeted cyberattack ?
Between Phonak US company and Medline company, which one has experienced at least one vulnerability ?
Between Phonak US company and Medline company, which one holds the most compliance certifications ?
Between Phonak US company and Medline company, which one holds the fewest compliance certifications ?
Between Phonak US company and Medline company, which one has the most subsidiaries ?
Between Phonak US company and Medline company, which one has the largest number of employees ?
Between Phonak US and Medline, which company holds both SOC 2 Type 1 certifications ?
Between Phonak US and Medline, which company holds both SOC 2 Type 2 certifications ?
Which company is ISO 27001 certified - Phonak US or Medline ?
Which company is PCI DSS compliant - Phonak US or Medline ?
Between Phonak US and Medline, which company complies with HIPAA regulations for healthcare data ?
Between Phonak US and Medline, which company complies with GDPR requirements ?

Latest Global CVEs

CVE-2026-49416
SUMMARY

The CONS_HISTORY ioctl handler did not adequately validate the requested history size. A large value caused an integer overflow in the buffer size calculation, resulting in a heap allocation smaller than expected. Subsequent initialization of the buffer wrote beyond the end of the allocation. An unprivileged local user with access to a vt(4) device can trigger an out-of-bounds write in the kernel, potentially escalating privileges.

PUBLISHED
Date2026-06-27
UPDATED
Date2026-06-27
IMPACT SCORE
NA
EXPLOITABILITY
NA
CVE-2026-49414
SUMMARY

The ELF image activator cleared per-process ASLR preference flags for setuid binaries after the code that computes the PIE base address, rather than before. As a result, a user-requested ASLR disable was still in effect at the point where the base address was chosen. An unprivileged local user can disable ASLR for a setuid PIE binary by calling procctl(2) before execve(2). This makes exploitation of any separate memory corruption vulnerability in that binary significantly easier.

PUBLISHED
Date2026-06-27
UPDATED
Date2026-06-27
IMPACT SCORE
NA
EXPLOITABILITY
NA
CVE-2026-49417
SUMMARY

Second, the audio buffer backing a mapping could be freed when the device was closed even though the mapping remained valid. The freed memory could then be reused elsewhere while still accessible through the stale mapping. The /dev/dsp device nodes are world-accessible by default. On a system with an audio device, either issue allows an unprivileged local user to read and write kernel memory, which can be used to escalate privileges, potentially gaining full control of the affected system. At a minimum, an attacker can crash the kernel, resulting in a Denial of Service (DoS).

PUBLISHED
Date2026-06-27
UPDATED
Date2026-06-27
IMPACT SCORE
NA
EXPLOITABILITY
NA
CVE-2026-49413
SUMMARY

The Linuxulator determined whether a binary was set-user-ID or set-group-ID by checking the P_SUGID process flag. During execve(2), this flag is not yet set at the point where the auxiliary vector is constructed, so AT_SECURE was incorrectly set to zero for set-user-ID and set-group-ID executables. An unprivileged local user can inject a shared library via LD_PRELOAD into a set-user-ID or set-group-ID Linux binary, gaining the privileges of that binary.

PUBLISHED
Date2026-06-27
UPDATED
Date2026-06-27
IMPACT SCORE
NA
EXPLOITABILITY
NA
CVE-2026-49412
SUMMARY

The kernel handler for IPV6_MSFILTER dropped a serializing lock in order to copy the source-filter list from userspace, then reacquired the lock. During this window another thread could free the multicast filter structure, leaving the handler with a stale pointer to freed memory. An unprivileged local user can exploit this use-after-free to escalate privileges.

PUBLISHED
Date2026-06-27
UPDATED
Date2026-06-27
IMPACT SCORE
NA
EXPLOITABILITY
NA