Rankiteo Logo
Rankiteo
Leader in Cyber Underwriting
Loading...
NEWRankiteo Cyber Underwriting Desktop - Score, price, and bind from your desktop
WindowsmacOSLinux
Download

Comparison Overview

Midea Building Technologies IndonesiaMidea Building Technologies Indonesia
VS
Carrier HVACCarrier HVAC
Midea Building Technologies Indonesia

Midea Building Technologies Indonesia

Jl. Pluit Selatan Raya Kav. 1 - Penjaringan, Jakarta Utara, DKI Jakarta, 14440, ID

Last Update: 18/11/2025

View Profile
744/1000Moderate

Midea HBT (HVAC & Building Technologies) adalah bagian dari Grup Midea, sebagai menyediakan solusi terkemuka untuk sumber energi, elevator, sistem kontrol, pemanas, dan pendingin udara. Midea HBT melanjutkan inovasi sebagai tradisi yang menjadi landasan dan muncul seb...

NAICS:333
NAICS Definition:N/A
Employees:47
Subsidiaries:19
12-month incidents
0
Known data breaches
0
Attack type number
0
Carrier HVAC

Carrier HVAC

US

Last Update: 01/04/2026

View Profile
Between 750 and 799
http://www.carrier.com
780/1000Fair

Carrier is a global leader in intelligent climate and energy solutions, pioneering sustainable innovations in climate technologies. Founded by Willis Carrier, the inventor of modern air conditioning, we have been shaping industries and enhancing lives for more than a ce...

NAICS:3332
NAICS Definition:Industrial Machinery Manufacturing
Employees:12,400
Subsidiaries:1
12-month incidents
0
Known data breaches
0
Attack type number
0

Compliance Ranges Comparison

Based On Specific Ai Models Category
Midea Building Technologies Indonesia

Midea Building Technologies Indonesia

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA
Carrier HVAC

Carrier HVAC

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA

Benchmark & Cyber Underwriting Signals

Incidents vs Industrial Machinery Manufacturing Industry Avg (This Year)

No incidents recorded for Midea Building Technologies Indonesia in 2026.

Incidents

Incidents vs Industrial Machinery Manufacturing Industry Avg (This Year)

No incidents recorded for Carrier HVAC in 2026.

Incidents

Incident History - Midea Building Technologies Indonesia (X = Date, Y = Severity)

Midea Building Technologies Indonesia cyber incidents detection timeline including parent company and subsidiaries.

No timeline data available
R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Incident History - Carrier HVAC (X = Date, Y = Severity)

Carrier HVAC cyber incidents detection timeline including parent company and subsidiaries.

No timeline data available
R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Notable Incidents

Last Cyber / HR Incidents / Global...
Midea Building Technologies Indonesia

Midea Building Technologies Indonesia

Incidents
No explicit notable incidents reported.
Carrier HVAC

Carrier HVAC

Incidents
No explicit notable incidents reported.

FAQ

Between Midea Building Technologies Indonesia company and Carrier HVAC company, which one has the best AI Cybersecurity Score ?
Between Midea Building Technologies Indonesia company and Carrier HVAC company, which one has experienced more cyber incidents in the past ?
Between Midea Building Technologies Indonesia company and Carrier HVAC company, which one has experienced more cyber incidents this year ?
Between Midea Building Technologies Indonesia company and Carrier HVAC company, which one has experienced at least one ransomware attack ?
Between Midea Building Technologies Indonesia company and Carrier HVAC company, which one has experienced at least one data breach ?
Between Midea Building Technologies Indonesia company and Carrier HVAC company, which one has experienced at least one targeted cyberattack ?
Between Midea Building Technologies Indonesia company and Carrier HVAC company, which one has experienced at least one vulnerability ?
Between Midea Building Technologies Indonesia company and Carrier HVAC company, which one holds the most compliance certifications ?
Between Midea Building Technologies Indonesia company and Carrier HVAC company, which one holds the fewest compliance certifications ?
Between Midea Building Technologies Indonesia company and Carrier HVAC company, which one has the most subsidiaries ?
Between Midea Building Technologies Indonesia company and Carrier HVAC company, which one has the largest number of employees ?
Between Midea Building Technologies Indonesia and Carrier HVAC, which company holds both SOC 2 Type 1 certifications ?
Between Midea Building Technologies Indonesia and Carrier HVAC, which company holds both SOC 2 Type 2 certifications ?
Which company is ISO 27001 certified - Midea Building Technologies Indonesia or Carrier HVAC ?
Which company is PCI DSS compliant - Midea Building Technologies Indonesia or Carrier HVAC ?
Between Midea Building Technologies Indonesia and Carrier HVAC, which company complies with HIPAA regulations for healthcare data ?
Between Midea Building Technologies Indonesia and Carrier HVAC, which company complies with GDPR requirements ?

Latest Global CVEs

CVE-2026-13512
SUMMARY

A vulnerability was identified in Databend up to 1.2.881 on HTTP. This affects the function ClientSessionManager::state_key of the file src/query/service/src/servers/http/v1/session/client_session_manager.rs of the component Tenant Handler. The manipulation leads to authorization bypass. It is possible to initiate the attack remotely. The exploit is publicly available and might be used. The pull request to fix this issue awaits acceptance.

PUBLISHED
Date2026-06-28
UPDATED
Date2026-06-28
RISK INFORMATION (Score: 6.3)
CVSS2
Base Score: 6.5
Complexity: LOW
AV:N/AC:L/Au:S/C:P/I:P/A:P
CVSS3
Base Score: 6.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CVSS4
Base Score: 2.1
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
3.4
EXPLOITABILITY
2.8
CVE-2026-13511
SUMMARY

A vulnerability was determined in VoltAgent up to 2.1.17. Affected by this issue is the function handleGetMemoryConversation of the file packages/server-core/src/handlers/memory.handlers.ts of the component Memory REST API. Executing a manipulation of the argument conversationId can lead to improper authorization. The attack may be performed from remote. This attack is characterized by high complexity. The exploitation is known to be difficult. The exploit has been publicly disclosed and may be utilized. The pull request to fix this issue awaits acceptance.

PUBLISHED
Date2026-06-28
UPDATED
Date2026-06-28
RISK INFORMATION (Score: 3.1)
CVSS2
Base Score: 2.1
Complexity: HIGH
AV:N/AC:H/Au:S/C:P/I:N/A:N
CVSS3
Base Score: 3.1
Complexity: HIGH
CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N
CVSS4
Base Score: 1.3
Complexity: HIGH
CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
1.4
EXPLOITABILITY
1.6
CVE-2026-13510
SUMMARY

A vulnerability was found in SimStudioAI sim up to 0.6.92. Affected by this vulnerability is an unknown functionality in the library apps/sim/lib/core/security/deployment.ts of the component Password Protection Handler. Performing a manipulation results in use of weak hash. The attack is possible to be carried out remotely. The attack's complexity is rated as high. The exploitation appears to be difficult. The exploit has been made public and could be used. The pull request to fix this issue awaits acceptance.

PUBLISHED
Date2026-06-28
UPDATED
Date2026-06-28
RISK INFORMATION (Score: 3.7)
CVSS2
Base Score: 2.6
Complexity: HIGH
AV:N/AC:H/Au:N/C:P/I:N/A:N
CVSS3
Base Score: 3.7
Complexity: HIGH
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N
CVSS4
Base Score: 2.9
Complexity: HIGH
CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
1.4
EXPLOITABILITY
2.2
CVE-2026-13509
SUMMARY

A vulnerability has been found in RAGapp up to 0.1.5. Affected is the function FileHandler.upload_file/FileHandler.remove_file of the file src/ragapp/backend/controllers/files.py of the component Knowledge File Handler. Such manipulation leads to path traversal. The attack can be executed remotely. The exploit has been disclosed to the public and may be used. The pull request to fix this issue awaits acceptance.

PUBLISHED
Date2026-06-28
UPDATED
Date2026-06-28
RISK INFORMATION (Score: 6.3)
CVSS2
Base Score: 6.5
Complexity: LOW
AV:N/AC:L/Au:S/C:P/I:P/A:P
CVSS3
Base Score: 6.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CVSS4
Base Score: 2.1
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
3.4
EXPLOITABILITY
2.8
CVE-2026-13508
SUMMARY

A flaw has been found in khoj-ai khoj up to 2.0.0-beta.28. This impacts an unknown function of the file src/khoj/routers/api_chat.py of the component Conversation Sharing Handler. This manipulation of the argument conversation.agent causes incorrect authorization. Remote exploitation of the attack is possible. The exploit has been published and may be used. The pull request to fix this issue awaits acceptance.

PUBLISHED
Date2026-06-28
UPDATED
Date2026-06-28
RISK INFORMATION (Score: 5.5)
CVSS2
Base Score: 6.5
Complexity: LOW
AV:N/AC:L/Au:S/C:P/I:P/A:P
CVSS3
Base Score: 5.5
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L
CVSS4
Base Score: 2.0
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
3.4
EXPLOITABILITY
2.1