Rankiteo Logo
Rankiteo
Leader in Cyber Underwriting
Loading...
NEWRankiteo Cyber Underwriting Desktop - Score, price, and bind from your desktop
WindowsmacOSLinux
Download

Comparison Overview

LTI Power SystemsLTI Power Systems
VS
Delta ElectronicsDelta Electronics
LTI Power Systems

LTI Power Systems

10800 Middle Ave Bldg B, Elyria, 44035-7890, US

Last Update: 02/04/2026

View Profile
726/1000Moderate

LTI Power Systems innovates, engineers, manufactures and supports a full line of Industrial True Online UPS and Inverter Systems that are Custom-Built with the highest reliability in the industry.

NAICS:335
NAICS Definition:Electrical Equipment, Appliance, and Component Manufacturing
Employees:7
Subsidiaries:0
12-month incidents
0
Known data breaches
0
Attack type number
1
Delta Electronics

Delta Electronics

瑞光路, 內湖區, 114, TW

Last Update: 01/04/2026

View Profile
Between 750 and 799
http://www.deltaww.com
765/1000Fair

Delta is a global innovative provider of switching power supplies and DC brushless fans, as well as a major source for power management solutions, components, visual displays, industrial automation, networking products, and renewable energy solutions. Delta Group has sa...

NAICS:335
NAICS Definition:Electrical Equipment, Appliance, and Component Manufacturing
Employees:16,020
Subsidiaries:14
12-month incidents
1
Known data breaches
1
Attack type number
2

Compliance Ranges Comparison

Based On Specific Ai Models Category
LTI Power Systems

LTI Power Systems

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA
Delta Electronics

Delta Electronics

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA

Benchmark & Cyber Underwriting Signals

Incidents vs Appliances, Electrical, and Electronics Manufacturing Industry Avg (This Year)

No incidents recorded for LTI Power Systems in 2026.

Incidents

Incidents vs Appliances, Electrical, and Electronics Manufacturing Industry Avg (This Year)

Delta Electronics has 2.91% fewer incidents than the average of all companies with at least one recorded incident.

Incidents

Incident History - LTI Power Systems (X = Date, Y = Severity)

LTI Power Systems cyber incidents detection timeline including parent company and subsidiaries.

R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Incident History - Delta Electronics (X = Date, Y = Severity)

Delta Electronics cyber incidents detection timeline including parent company and subsidiaries.

R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Notable Incidents

Last Cyber / HR Incidents / Global...
LTI Power Systems

LTI Power Systems

Incidents
🔒 Incident : Ransomware
LTI1129822
Delta Electronics

Delta Electronics

Incidents
🔒 Incident : Breach
DEL1770767540
🔒 Incident : Ransomware
DEL11023422

FAQ

Between LTI Power Systems company and Delta Electronics company, which one has the best AI Cybersecurity Score ?
Between LTI Power Systems company and Delta Electronics company, which one has experienced more cyber incidents in the past ?
Between LTI Power Systems company and Delta Electronics company, which one has experienced more cyber incidents this year ?
Between LTI Power Systems company and Delta Electronics company, which one has experienced at least one ransomware attack ?
Between LTI Power Systems company and Delta Electronics company, which one has experienced at least one data breach ?
Between LTI Power Systems company and Delta Electronics company, which one has experienced at least one targeted cyberattack ?
Between LTI Power Systems company and Delta Electronics company, which one has experienced at least one vulnerability ?
Between LTI Power Systems company and Delta Electronics company, which one holds the most compliance certifications ?
Between LTI Power Systems company and Delta Electronics company, which one holds the fewest compliance certifications ?
Between LTI Power Systems company and Delta Electronics company, which one has the most subsidiaries ?
Between LTI Power Systems company and Delta Electronics company, which one has the largest number of employees ?
Between LTI Power Systems and Delta Electronics, which company holds both SOC 2 Type 1 certifications ?
Between LTI Power Systems and Delta Electronics, which company holds both SOC 2 Type 2 certifications ?
Which company is ISO 27001 certified - LTI Power Systems or Delta Electronics ?
Which company is PCI DSS compliant - LTI Power Systems or Delta Electronics ?
Between LTI Power Systems and Delta Electronics, which company complies with HIPAA regulations for healthcare data ?
Between LTI Power Systems and Delta Electronics, which company complies with GDPR requirements ?

Latest Global CVEs

CVE-2026-82592
SUMMARY

A vulnerability was detected in D-Link DIR-825M 1.1.8. This affects the function sub_46725C of the file /boafrm/formDiskFormat of the component Disk Formatting Handler Endpoint. The manipulation of the argument partition results in stack-based buffer overflow. The attack can be executed remotely. The exploit is now public and may be used.

PUBLISHED
Date2026-08-30
UPDATED
Date2026-08-30
RISK INFORMATION (Score: 9.9)
CVSS2
Base Score: 9.0
Complexity: LOW
AV:N/AC:L/Au:S/C:C/I:C/A:C
CVSS3
Base Score: 9.9
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
CVSS4
Base Score: 8.6
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
6
EXPLOITABILITY
3.1
CVE-2026-82591
SUMMARY

A security vulnerability has been detected in Open Asset Import Library Assimp up to 6.0.2. The impacted element is the function MD5Importer::MakeDataUnique of the file code/AssetLib/MD5/MD5Loader.cpp. The manipulation of the argument iNewIndex leads to heap-based buffer overflow. The attack can only be performed from a local environment. The identifier of the patch is bf9dabb617c46e5133dac65cca6bff177917afcb. Applying a patch is the recommended action to fix this issue.

PUBLISHED
Date2026-08-30
UPDATED
Date2026-08-30
RISK INFORMATION (Score: 5.3)
CVSS2
Base Score: 4.3
Complexity: LOW
AV:L/AC:L/Au:S/C:P/I:P/A:P
CVSS3
Base Score: 5.3
Complexity: LOW
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CVSS4
Base Score: 4.8
Complexity: LOW
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
3.4
EXPLOITABILITY
1.8
CVE-2026-82590
SUMMARY

A weakness has been identified in Open5GS up to 2.7.7. The affected element is the function smf_nudm_sdm_handle_get of the file src/smf/nudm-handler.c of the component SMF. Executing a manipulation of the argument preemptCap can lead to reachable assertion. The attack may be launched remotely. Upgrading to version 2.8.0 is sufficient to fix this issue. This patch is called 4554405f29bffd7562abedbee63484825bd90cd5. You should upgrade the affected component.

PUBLISHED
Date2026-08-30
UPDATED
Date2026-08-30
RISK INFORMATION (Score: 4.3)
CVSS2
Base Score: 4.0
Complexity: LOW
AV:N/AC:L/Au:S/C:N/I:N/A:P
CVSS3
Base Score: 4.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L
CVSS4
Base Score: 5.3
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
1.4
EXPLOITABILITY
2.8
CVE-2026-82589
SUMMARY

A security flaw has been discovered in Open5GS up to 2.7.7. Impacted is the function amf_namf_comm_handle_n1_n2_message_transfer of the file src/amf/namf-handler.c of the component N1-N2 Message Handler. Performing a manipulation of the argument N1N2MessageTransferReqData.n2InfoContainer.smInfo.n2InfoContent.ngapIeType results in denial of service. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks. Upgrading to version 2.8.0 is recommended to address this issue. The patch is named abf8a836564b966b5141110fc25ed413c4f17522. It is advisable to upgrade the affected component.

PUBLISHED
Date2026-08-30
UPDATED
Date2026-08-30
RISK INFORMATION (Score: 4.3)
CVSS2
Base Score: 4.0
Complexity: LOW
AV:N/AC:L/Au:S/C:N/I:N/A:P
CVSS3
Base Score: 4.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L
CVSS4
Base Score: 2.1
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
1.4
EXPLOITABILITY
2.8
CVE-2026-82588
SUMMARY

A vulnerability was identified in Open5GS up to 2.7.7. This issue affects some unknown processing of the file src/amf/namf-handler.c of the component Transfer Endpoint. Such manipulation leads to null pointer dereference. The attack can be launched remotely. Upgrading to version 2.8.0 is capable of addressing this issue. The name of the patch is abf8a836564b966b5141110fc25ed413c4f17522. Upgrading the affected component is advised.

PUBLISHED
Date2026-08-30
UPDATED
Date2026-08-30
RISK INFORMATION (Score: 4.3)
CVSS2
Base Score: 4.0
Complexity: LOW
AV:N/AC:L/Au:S/C:N/I:N/A:P
CVSS3
Base Score: 4.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L
CVSS4
Base Score: 5.3
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
1.4
EXPLOITABILITY
2.8