Rankiteo Logo
Rankiteo
Leader in Cyber Underwriting
Loading...
NEWRankiteo Cyber Underwriting Desktop - Score, price, and bind from your desktop
WindowsmacOSLinux
Download

Comparison Overview

Littmann StethoscopesLittmann Stethoscopes
VS
Olympus CorporationOlympus Corporation
Littmann Stethoscopes

Littmann Stethoscopes

3M Corporate Headquarters , St. Paul, Minnesota , 55144, US

Last Update: 30/12/2025

View Profile
755/1000Fair

The stethoscope represents listening, care and a connection with patients. At Littmann, our journey to quality, innovation and being a leader in auscultation technology starts with listening to you.

NAICS:339
NAICS Definition:N/A
Employees:1
Subsidiaries:2
12-month incidents
0
Known data breaches
0
Attack type number
0
Olympus Corporation

Olympus Corporation

Nishi-shinjuku 2-3-1 Shinjuku Monolith, Shinjuku-ku, JP

Last Update: 01/04/2026

View Profile
791/1000Fair

Olympus is passionate about creating customer-driven solutions for the medical industry. For more than 100 years, Olympus has focused on making people’s lives healthier, safer and more fulfilling by helping detect, prevent, and treat disease, furthering scientific resea...

NAICS:3391
NAICS Definition:Medical Equipment and Supplies Manufacturing
Employees:13,565
Subsidiaries:0
12-month incidents
0
Known data breaches
0
Attack type number
0

Compliance Ranges Comparison

Based On Specific Ai Models Category
Littmann Stethoscopes

Littmann Stethoscopes

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA
Olympus Corporation

Olympus Corporation

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA

Benchmark & Cyber Underwriting Signals

Incidents vs Medical Equipment Manufacturing Industry Avg (This Year)

No incidents recorded for Littmann Stethoscopes in 2026.

Incidents

Incidents vs Medical Equipment Manufacturing Industry Avg (This Year)

No incidents recorded for Olympus Corporation in 2026.

Incidents

Incident History - Littmann Stethoscopes (X = Date, Y = Severity)

Littmann Stethoscopes cyber incidents detection timeline including parent company and subsidiaries.

R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Incident History - Olympus Corporation (X = Date, Y = Severity)

Olympus Corporation cyber incidents detection timeline including parent company and subsidiaries.

No timeline data available
R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Notable Incidents

Last Cyber / HR Incidents / Global...
Littmann Stethoscopes

Littmann Stethoscopes

Incidents
No explicit notable incidents reported.
Olympus Corporation

Olympus Corporation

Incidents
No explicit notable incidents reported.

FAQ

Between Littmann Stethoscopes company and Olympus Corporation company, which one has the best AI Cybersecurity Score ?
Between Littmann Stethoscopes company and Olympus Corporation company, which one has experienced more cyber incidents in the past ?
Between Littmann Stethoscopes company and Olympus Corporation company, which one has experienced more cyber incidents this year ?
Between Littmann Stethoscopes company and Olympus Corporation company, which one has experienced at least one ransomware attack ?
Between Littmann Stethoscopes company and Olympus Corporation company, which one has experienced at least one data breach ?
Between Littmann Stethoscopes company and Olympus Corporation company, which one has experienced at least one targeted cyberattack ?
Between Littmann Stethoscopes company and Olympus Corporation company, which one has experienced at least one vulnerability ?
Between Littmann Stethoscopes company and Olympus Corporation company, which one holds the most compliance certifications ?
Between Littmann Stethoscopes company and Olympus Corporation company, which one holds the fewest compliance certifications ?
Between Littmann Stethoscopes company and Olympus Corporation company, which one has the most subsidiaries ?
Between Littmann Stethoscopes company and Olympus Corporation company, which one has the largest number of employees ?
Between Littmann Stethoscopes and Olympus Corporation, which company holds both SOC 2 Type 1 certifications ?
Between Littmann Stethoscopes and Olympus Corporation, which company holds both SOC 2 Type 2 certifications ?
Which company is ISO 27001 certified - Littmann Stethoscopes or Olympus Corporation ?
Which company is PCI DSS compliant - Littmann Stethoscopes or Olympus Corporation ?
Between Littmann Stethoscopes and Olympus Corporation, which company complies with HIPAA regulations for healthcare data ?
Between Littmann Stethoscopes and Olympus Corporation, which company complies with GDPR requirements ?

Latest Global CVEs

CVE-2026-12814
SUMMARY

A flaw has been found in Comfast CF-WR631AX V3 up to 2.7.0.8. This issue affects the function system of the file /cgi-bin/mbox-config?section=ping_config of the component API Endpoint. This manipulation of the argument destination causes os command injection. The attack is possible to be carried out remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

PUBLISHED
Date2026-06-21
UPDATED
Date2026-06-21
RISK INFORMATION (Score: 6.3)
CVSS2
Base Score: 6.5
Complexity: LOW
AV:N/AC:L/Au:S/C:P/I:P/A:P
CVSS3
Base Score: 6.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CVSS4
Base Score: 2.1
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
3.4
EXPLOITABILITY
2.8
CVE-2026-12813
SUMMARY

A vulnerability was detected in activepieces up to 0.83.0. This vulnerability affects the function handleUrlFile in the library packages/server/engine/src/lib/variables/processors/file.ts of the component File URL Handler. The manipulation results in server-side request forgery. The attack can be executed remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

PUBLISHED
Date2026-06-21
UPDATED
Date2026-06-21
RISK INFORMATION (Score: 6.3)
CVSS2
Base Score: 6.5
Complexity: LOW
AV:N/AC:L/Au:S/C:P/I:P/A:P
CVSS3
Base Score: 6.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CVSS4
Base Score: 2.1
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
3.4
EXPLOITABILITY
2.8
CVE-2026-12812
SUMMARY

A security vulnerability has been detected in Radware Cyber Controller up to 10.11.0. This affects an unknown part of the component HTML Report Generation. The manipulation leads to HTML injection. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

PUBLISHED
Date2026-06-21
UPDATED
Date2026-06-21
RISK INFORMATION (Score: 3.5)
CVSS2
Base Score: 4.0
Complexity: LOW
AV:N/AC:L/Au:S/C:N/I:P/A:N
CVSS3
Base Score: 3.5
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N
CVSS4
Base Score: 2.0
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
1.4
EXPLOITABILITY
2.1
CVE-2026-12811
SUMMARY

A weakness has been identified in kortix-ai suna up to 0.8.38. Affected by this issue is the function router.replace/router.push of the file apps/frontend/src/app/auth/page.tsx of the component Auth Endpoint. Executing a manipulation of the argument returnURL can lead to cross site scripting. The attack may be launched remotely. The exploit has been made available to the public and could be used for attacks. Upgrading to version 0.8.39 can resolve this issue. This patch is called f5dec7aa0c1b8fa0125938f292c0f2430ca75f6c. It is advisable to upgrade the affected component. The researcher explains: "The issue was fixed in v0.8.39 without notifying the wider user base via a security disclosure."

PUBLISHED
Date2026-06-21
UPDATED
Date2026-06-21
RISK INFORMATION (Score: 4.3)
CVSS2
Base Score: 5.0
Complexity: LOW
AV:N/AC:L/Au:N/C:N/I:P/A:N
CVSS3
Base Score: 4.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N
CVSS4
Base Score: 2.1
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
1.4
EXPLOITABILITY
2.8
CVE-2026-12810
SUMMARY

A security flaw has been discovered in Edimax BR-6478AC V2 1.23. Affected by this vulnerability is the function mp of the file /goform/mp of the component POST Request Handler. Performing a manipulation of the argument command results in command injection. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.

PUBLISHED
Date2026-06-21
UPDATED
Date2026-06-21
RISK INFORMATION (Score: 6.3)
CVSS2
Base Score: 6.5
Complexity: LOW
AV:N/AC:L/Au:S/C:P/I:P/A:P
CVSS3
Base Score: 6.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CVSS4
Base Score: 2.1
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
3.4
EXPLOITABILITY
2.8