Rankiteo Logo
Rankiteo
Leader in Cyber Underwriting
Loading...
NEWRankiteo Cyber Underwriting Desktop - Score, price, and bind from your desktop
WindowsmacOSLinux
Download

Comparison Overview

Leica Microsystems MedicalLeica Microsystems Medical
VS
Emory HealthcareEmory Healthcare
Leica Microsystems Medical

Leica Microsystems Medical

N/A

Last Update: 29/11/2025

View Profile
758/1000Fair

Welcome to the Medical LinkedIn Page of Leica Microsystems! Our medical product portfolio provides microscope solutions for medical professionals in various clinical specialities: spine surgery, neurosurgery, plastic reconstructive surgery, surgical and non-surgical ...

NAICS:62
NAICS Definition:Health Care and Social Assistance
Employees:13
Subsidiaries:65
12-month incidents
0
Known data breaches
0
Attack type number
0
Emory Healthcare

Emory Healthcare

Emory University Hospital, Atlanta, 30322, US

Last Update: 05/04/2026

View Profile
737/1000Moderate

Emory Healthcare is the most comprehensive health care system in Georgia. We offer 11 hospitals, the Emory Clinic, more than 250 provider locations, and more than 2,800 physicians specializing in 70 different medical subspecialties. Meaning we can provide treatments and...

NAICS:62
NAICS Definition:Health Care and Social Assistance
Employees:16,617
Subsidiaries:0
12-month incidents
0
Known data breaches
1
Attack type number
2

Compliance Ranges Comparison

Based On Specific Ai Models Category
Leica Microsystems Medical

Leica Microsystems Medical

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA
Emory Healthcare

Emory Healthcare

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA

Benchmark & Cyber Underwriting Signals

Incidents vs Hospitals and Health Care Industry Avg (This Year)

No incidents recorded for Leica Microsystems Medical in 2026.

Incidents

Incidents vs Hospitals and Health Care Industry Avg (This Year)

No incidents recorded for Emory Healthcare in 2026.

Incidents

Incident History - Leica Microsystems Medical (X = Date, Y = Severity)

Leica Microsystems Medical cyber incidents detection timeline including parent company and subsidiaries.

No timeline data available
R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Incident History - Emory Healthcare (X = Date, Y = Severity)

Emory Healthcare cyber incidents detection timeline including parent company and subsidiaries.

R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Notable Incidents

Last Cyber / HR Incidents / Global...
Leica Microsystems Medical

Leica Microsystems Medical

Incidents
No explicit notable incidents reported.
Emory Healthcare

Emory Healthcare

Incidents
🔒 Incident : Cyber Attack
EMO729051525
🔒 Incident : Breach
EMO118251222

FAQ

Between Leica Microsystems Medical company and Emory Healthcare company, which one has the best AI Cybersecurity Score ?
Between Leica Microsystems Medical company and Emory Healthcare company, which one has experienced more cyber incidents in the past ?
Between Leica Microsystems Medical company and Emory Healthcare company, which one has experienced more cyber incidents this year ?
Between Leica Microsystems Medical company and Emory Healthcare company, which one has experienced at least one ransomware attack ?
Between Leica Microsystems Medical company and Emory Healthcare company, which one has experienced at least one data breach ?
Between Leica Microsystems Medical company and Emory Healthcare company, which one has experienced at least one targeted cyberattack ?
Between Leica Microsystems Medical company and Emory Healthcare company, which one has experienced at least one vulnerability ?
Between Leica Microsystems Medical company and Emory Healthcare company, which one holds the most compliance certifications ?
Between Leica Microsystems Medical company and Emory Healthcare company, which one holds the fewest compliance certifications ?
Between Leica Microsystems Medical company and Emory Healthcare company, which one has the most subsidiaries ?
Between Leica Microsystems Medical company and Emory Healthcare company, which one has the largest number of employees ?
Between Leica Microsystems Medical and Emory Healthcare, which company holds both SOC 2 Type 1 certifications ?
Between Leica Microsystems Medical and Emory Healthcare, which company holds both SOC 2 Type 2 certifications ?
Which company is ISO 27001 certified - Leica Microsystems Medical or Emory Healthcare ?
Which company is PCI DSS compliant - Leica Microsystems Medical or Emory Healthcare ?
Between Leica Microsystems Medical and Emory Healthcare, which company complies with HIPAA regulations for healthcare data ?
Between Leica Microsystems Medical and Emory Healthcare, which company complies with GDPR requirements ?

Latest Global CVEs

CVE-2026-44453
SUMMARY

h2o is an HTTP server with support for HTTP/1.x, HTTP/2 and HTTP/3. Prior to commit 6b5370d, h2o is vulnerable to a Denial of Service attack when calling alloca under certain conditions. When serving static files, h2o builds the file path on stack, by calling alloca. The maximum size of the memory allocated using alloca can be as huge as ~600KB, which exceeds the default pthread stack size used by musl libc (128KB). If the amount of memory allocated by alloca exceeds the stack size, the h2o server crashes with a segmentation fault, while it tries to touch the guard page. This issue has been fixed by commit 6b5370d.

PUBLISHED
Date2026-07-16
UPDATED
Date2026-07-16
RISK INFORMATION (Score: 7.5)
CVSS3
Base Score: 7.5
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
IMPACT SCORE
3.6
EXPLOITABILITY
3.9
CVE-2026-44452
SUMMARY

h2o is an HTTP server with support for HTTP/1.x, HTTP/2 and HTTP/3. Prior to commit 8dc37cb, when h2o receives a ClientHello message over TLS or QUIC and it contains a zero-length SNI extension, the h2o server runs over the zero-length hostname while trying to copy the hostname, assuming that it is NULL-terminated. This is a potential denial-of-service attack vector in sense that it might trigger segmentation violation. This issue has been fixed by commit 8dc37cb.

PUBLISHED
Date2026-07-16
UPDATED
Date2026-07-16
RISK INFORMATION (Score: 5.9)
CVSS3
Base Score: 5.9
Complexity: HIGH
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H
IMPACT SCORE
3.6
EXPLOITABILITY
2.2
CVE-2026-44436
SUMMARY

Quicly is an IETF QUIC protocol implementation intended primarily for use within the H2O HTTP server. Prior to commit 8b178e6, Quicly is vulnerable to a Denial of Service attack through connection state corruption. In QUIC Invariants, the maximum length of a Connection ID is 255 bytes, while QUIC version 1 further restricts the maximum to 20 bytes. Quicly implements QUIC version 1 and therefore its CID buffers are limited to 20 bytes. However, to be able to respond to unknown versions of QUIC, its packet decoder accepts Connection IDs of up to 255 bytes. As its CID buffers are merely 20 bytes long, Quicly must reject QUIC version 1 packets with Connection IDs longer than that. The command line tool bundled with Quicly has had that check, however the library itself lacked such enforcement. As a consequence, when used by applications that lack their own enforcement, the connection state becoming inconsistent to buffer overrun. Fortunately, the overflow stops within the allocated chunk of memory, but nevertheless, the bug leads to assertion failures. This issue has been fixed by commit 8b178e6.

PUBLISHED
Date2026-07-16
UPDATED
Date2026-07-16
RISK INFORMATION (Score: 7.5)
CVSS3
Base Score: 7.5
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
IMPACT SCORE
3.6
EXPLOITABILITY
3.9
CVE-2026-44435
SUMMARY

Quicly is an IETF QUIC protocol implementation intended primarily for use within the H2O HTTP server. Prior to commit 937d0e9, an assertion failure is raised when the total number of valid handshake messages received over a CRYPTO stream of a single packet number space exceeds 32KB, causing a Denial of Service. This issue has been fixed by commit 937d0e9.

PUBLISHED
Date2026-07-16
UPDATED
Date2026-07-16
RISK INFORMATION (Score: 7.5)
CVSS3
Base Score: 7.5
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
IMPACT SCORE
3.6
EXPLOITABILITY
3.9
CVE-2026-44434
SUMMARY

Quicly is an IETF QUIC protocol implementation intended primarily for use within the H2O HTTP server. Prior to commit dccf5d4, Quicly was vulnerable to stateless reset injection through lack of packet entry validation. The QUIC protocol is designed to withstand packet injection attacks, once the handshake is complete. Only packets that carry some secret patterns are considered as stateless resets. Quicly allows the peer to share up to 4 such patterns per connection. However, until now, it failed to determine which of the 4 slots that it uses to retain the secret patterns contains a valid entry. As the slots are zero-initialized, the failure meant that, unless the peer advertised 4 of such patterns, an all-zero pattern was treated as a stateless reset.In effect, this allowed an on-path attacker to reset QUIC connections governed by Quicly. This issue has been fixed by commit dccf5d4.

PUBLISHED
Date2026-07-16
UPDATED
Date2026-07-16
RISK INFORMATION (Score: 5.3)
CVSS3
Base Score: 5.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
IMPACT SCORE
1.4
EXPLOITABILITY
3.9