Comparison Overview
Industrial Water & Wastewater Solutions

Industrial Water & Wastewater Solutions
6306 N Alpine Rd, Loves Park, 61111-4396, US
Last Update: 09/05/2026
Aqua-Aerobic Systems is an applied engineering company specializing in advanced water and wastewater solutions including aeration/mixing, biological processes, filtration, oxidation and disinfection, membranes, and process control for municipalities and industry.

Republic Services
18500 N. Allied Way, Phoenix, 85054, US
Last Update: 03/04/2026
Republic Services provides the most complete set of recycling, waste and environmental solutions from a single-source provider. We partner with customers to help them achieve their sustainability goals, driving both environmental and economic sustainability. We offer ad...
Compliance Ranges Comparison

Industrial Water & Wastewater Solutions







Republic Services






Benchmark & Cyber Underwriting Signals
Incidents vs Environmental Services Industry Avg (This Year)
No incidents recorded for Industrial Water & Wastewater Solutions in 2026.
Incidents vs Environmental Services Industry Avg (This Year)
No incidents recorded for Republic Services in 2026.
Incident History - Industrial Water & Wastewater Solutions (X = Date, Y = Severity)
Industrial Water & Wastewater Solutions cyber incidents detection timeline including parent company and subsidiaries.
Incident History - Republic Services (X = Date, Y = Severity)
Republic Services cyber incidents detection timeline including parent company and subsidiaries.
Notable Incidents

Industrial Water & Wastewater Solutions

Republic Services
FAQ
Latest Global CVEs
MOOS-IvP through 24.8.1 fails to properly validate variable names extracted from alog files in the SplitHandler, allowing attackers to write files outside the split directory. Attackers can supply crafted alog files with backslash sequences in variable names to escape the output directory and append to arbitrary files on Windows systems.
- https://github.com/moos-ivp/moos-ivp
- https://github.com/moos-ivp/moos-ivp/blob/1de9ae146cd63c209e8c3fd81611a4ed2472971b/ivp/src/lib_logutils/SplitHandler.cpp#L189
- https://github.com/moos-ivp/moos-ivp/commit/6f0619e905b325d6b88f76425673045c6e4f6f94
- https://github.com/moos-ivp/moos-ivp/pull/137
- https://www.vulncheck.com/advisories/moos-ivp-through-24.8.1-alog-splitting-path-traversal-on-windows
MOOS core-moos through 10.4.0 contains a buffer over-read vulnerability in CMOOSCommPkt where a four-byte packet triggers out-of-bounds memory access during deserialization. Attackers can open a TCP connection to the MOOSDB port and send a crafted short packet to read memory before authentication.
- https://github.com/themoos/core-moos
- https://github.com/themoos/core-moos/blob/ec9c77c68fcbdef8f5e4c60fe243acd223433f0c/Core/libMOOS/Comms/MOOSCommPkt.cpp#L228
- https://github.com/themoos/core-moos/commit/d30c14585753f9ae39749d9628ed15c8383f0568
- https://github.com/themoos/core-moos/pull/75
- https://www.vulncheck.com/advisories/moos-core-moos-through-10.4.0-moosdb-out-of-bounds-read-via-short-packet
MOOS core-moos through 10.4.0 contains a buffer overflow vulnerability in CMOOSSerialPort::GetTelegram() that writes a NUL terminator one byte past the serial telegram stack buffer. Attackers controlling the serial line can send a full-length telegram to trigger the off-by-one write, corrupting the stack and potentially enabling code execution.
- https://github.com/themoos/core-moos
- https://github.com/themoos/core-moos/blob/ec9c77c68fcbdef8f5e4c60fe243acd223433f0c/Core/libMOOS/Utils/MOOSSerialPort.cpp#L595
- https://github.com/themoos/core-moos/commit/befb04df2039d0080715ea35f56268092db4ec0f
- https://github.com/themoos/core-moos/pull/73
- https://www.vulncheck.com/advisories/moos-core-moos-through-10.4.0-off-by-one-buffer-overflow-in-serial-telegram-handling
MOOS core-moos through 10.4.0 fails to escape database contents when rendering MOOSDB HTTP pages, allowing attackers to inject malicious scripts. Any MOOS publisher can set variable values containing script payloads that execute in the browser of operators viewing the web interface.
- https://github.com/themoos/core-moos
- https://github.com/themoos/core-moos/blob/ec9c77c68fcbdef8f5e4c60fe243acd223433f0c/Core/libMOOS/DB/HTTPConnection.cpp#L460
- https://github.com/themoos/core-moos/commit/a3f26f099bb08decb143f704d8b1ca16ae405b44
- https://github.com/themoos/core-moos/pull/78
- https://www.vulncheck.com/advisories/moos-core-moos-through-10.4.0-moosdb-http-pages-stored-cross-site-scripting
MOOS ui-moos through 50b9c6c contains a buffer overflow vulnerability in ScopeTabPane.cpp and ScopeGrid.cpp where client and variable names are formatted into fixed 1024-byte buffers using sprintf without length validation. Attackers can supply arbitrarily long MOOS identifiers that overflow the buffers when an operator selects process list entries or pokes variables, enabling code execution.
- https://github.com/themoos/ui-moos
- https://github.com/themoos/ui-moos/blob/50b9c6c65169c501f746cfef1e167f74a7735e74/Tools/Graphical/uMS/ScopeTabPane.cpp#L243
- https://github.com/themoos/ui-moos/commit/a6ebc0bc6cb360315ce620e865f996d189cddb0e
- https://github.com/themoos/ui-moos/pull/5
- https://www.vulncheck.com/advisories/moos-ui-moos-through-50b9c6c-ums-buffer-overflow-via-long-moos-identifiers