Rankiteo Logo
Rankiteo
Leader in Cyber Underwriting
Loading...
NEWRankiteo Cyber Underwriting Desktop - Score, price, and bind from your desktop
WindowsmacOSLinux
Download

Comparison Overview

Healthcare.comHealthcare.com
VS
HumanaHumana
Healthcare.com

Healthcare.com

3401 N Miami Avenue, Miami, 33127, US

Last Update: 30/03/2026

View Profile
700/1000Moderate

Founded by industry experts in 2014, Healthcare.com is a data-driven, intelligence-informed marketplace where millions of consumers have explored, shopped for and enrolled in health insurance and Medicare plans. We put care, data, and a decade of experience into helpin...

NAICS:524
NAICS Definition:Insurance Carriers and Related Activities
Employees:199
Subsidiaries:0
12-month incidents
0
Known data breaches
1
Attack type number
1
Humana

Humana

500 W Main St, Louisville, US

Last Update: 01/04/2026

View Profile
Between 550 and 599
https://careers.humana.com/
556/1000Very Poor

Humana will never ask, nor require a candidate to provide money for work equipment and network access during the application process. If you become aware of any instances where you as a candidate are asked to provide information and do not believe it is a legitimate req...

NAICS:524
NAICS Definition:Insurance Carriers and Related Activities
Employees:46,895
Subsidiaries:6
12-month incidents
0
Known data breaches
5
Attack type number
3

Compliance Ranges Comparison

Based On Specific Ai Models Category
Healthcare.com

Healthcare.com

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA
Humana

Humana

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA

Benchmark & Cyber Underwriting Signals

Incidents vs Insurance Industry Avg (This Year)

No incidents recorded for Healthcare.com in 2026.

Incidents

Incidents vs Insurance Industry Avg (This Year)

No incidents recorded for Humana in 2026.

Incidents

Incident History - Healthcare.com (X = Date, Y = Severity)

Healthcare.com cyber incidents detection timeline including parent company and subsidiaries.

R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Incident History - Humana (X = Date, Y = Severity)

Humana cyber incidents detection timeline including parent company and subsidiaries.

R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Notable Incidents

Last Cyber / HR Incidents / Global...
Healthcare.com

Healthcare.com

Incidents
🔒 Incident : Breach
HEA926051325
Humana

Humana

Incidents
🔒 Incident : Ransomware
HUMORAHEACEN1774290394
🔒 Incident : Breach
HUM143072625
🔒 Incident : Cyber Attack
HUM030090625

FAQ

Between Healthcare.com company and Humana company, which one has the best AI Cybersecurity Score ?
Between Healthcare.com company and Humana company, which one has experienced more cyber incidents in the past ?
Between Healthcare.com company and Humana company, which one has experienced more cyber incidents this year ?
Between Healthcare.com company and Humana company, which one has experienced at least one ransomware attack ?
Between Healthcare.com company and Humana company, which one has experienced at least one data breach ?
Between Healthcare.com company and Humana company, which one has experienced at least one targeted cyberattack ?
Between Healthcare.com company and Humana company, which one has experienced at least one vulnerability ?
Between Healthcare.com company and Humana company, which one holds the most compliance certifications ?
Between Healthcare.com company and Humana company, which one holds the fewest compliance certifications ?
Between Healthcare.com company and Humana company, which one has the most subsidiaries ?
Between Healthcare.com company and Humana company, which one has the largest number of employees ?
Between Healthcare.com and Humana, which company holds both SOC 2 Type 1 certifications ?
Between Healthcare.com and Humana, which company holds both SOC 2 Type 2 certifications ?
Which company is ISO 27001 certified - Healthcare.com or Humana ?
Which company is PCI DSS compliant - Healthcare.com or Humana ?
Between Healthcare.com and Humana, which company complies with HIPAA regulations for healthcare data ?
Between Healthcare.com and Humana, which company complies with GDPR requirements ?

Latest Global CVEs

CVE-2026-14776
SUMMARY

A security flaw has been discovered in SourceCodester Onlne Examination & Learning Management System 1.0. Affected by this vulnerability is the function pathinfo of the file /upload_files.php of the component Filename Extension. Performing a manipulation results in unrestricted upload. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks. The name of the affected product appears to have a typo in it.

PUBLISHED
Date2026-07-05
UPDATED
Date2026-07-05
RISK INFORMATION (Score: 6.3)
CVSS2
Base Score: 6.5
Complexity: LOW
AV:N/AC:L/Au:S/C:P/I:P/A:P
CVSS3
Base Score: 6.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CVSS4
Base Score: 2.1
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
3.4
EXPLOITABILITY
2.8
CVE-2026-14775
SUMMARY

A vulnerability was identified in SourceCodester Onlne Examination & Learning Management System 1.0. Affected is an unknown function of the file /process_lesson.php. Such manipulation of the argument user_id leads to unrestricted upload. The attack may be launched remotely. The exploit is publicly available and might be used. The name of the affected product appears to have a typo in it.

PUBLISHED
Date2026-07-05
UPDATED
Date2026-07-05
RISK INFORMATION (Score: 6.3)
CVSS2
Base Score: 6.5
Complexity: LOW
AV:N/AC:L/Au:S/C:P/I:P/A:P
CVSS3
Base Score: 6.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CVSS4
Base Score: 2.1
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
3.4
EXPLOITABILITY
2.8
CVE-2026-14774
SUMMARY

A vulnerability was determined in itsourcecode Hospital Management System 1.0. This impacts an unknown function of the file /paymentdischarge.php. This manipulation of the argument patientid causes sql injection. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.

PUBLISHED
Date2026-07-05
UPDATED
Date2026-07-05
RISK INFORMATION (Score: 6.3)
CVSS2
Base Score: 6.5
Complexity: LOW
AV:N/AC:L/Au:S/C:P/I:P/A:P
CVSS3
Base Score: 6.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CVSS4
Base Score: 2.1
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
3.4
EXPLOITABILITY
2.8
CVE-2026-14773
SUMMARY

A vulnerability was found in itsourcecode Hospital Management System 1.0. This affects an unknown function of the file /payment.php. The manipulation of the argument patientid results in sql injection. The attack can be launched remotely. The exploit has been made public and could be used.

PUBLISHED
Date2026-07-05
UPDATED
Date2026-07-05
RISK INFORMATION (Score: 6.3)
CVSS2
Base Score: 6.5
Complexity: LOW
AV:N/AC:L/Au:S/C:P/I:P/A:P
CVSS3
Base Score: 6.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CVSS4
Base Score: 2.1
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
3.4
EXPLOITABILITY
2.8
CVE-2026-10657
SUMMARY

Zephyr's DNS resolver detects mDNS (.local) queries in dns_resolve_name_internal() (subsys/net/lib/dns/resolve.c) with memcmp(strrchr(query, '.'), ".local", 7), which always reads a fixed 7 bytes from the suffix pointer. When the resolved hostname's final label is shorter than 7 bytes (e.g. names ending in .org, .com, .net, .io, or a trailing dot), the comparison reads 1-2 bytes past the string's NUL terminator. The hostname (query) is the caller-supplied name passed through the standard getaddrinfo()/dns_get_addr_info()/dns_resolve_name() path and is influenceable by operators or remote inputs (server names from configuration, parsed URLs, or app-facing interfaces). On a tightly-sized buffer with no slack (for example a userspace getaddrinfo call where the hostname is copied with k_usermode_string_alloc_copy to exactly strlen+1 bytes), the over-read crosses the allocation boundary; if that boundary is unmapped (guard page, memory-domain boundary under MPU, or an address sanitizer) the over-read faults, causing a denial of service. The over-read bytes are never returned, so there is no information disclosure. The flaw is compiled only when CONFIG_MDNS_RESOLVER is enabled, exists since v1.10.0, and is fixed by replacing the fixed-length memcmp with a NUL-safe strcmp(ptr, ".local").

PUBLISHED
Date2026-07-05
UPDATED
Date2026-07-05
RISK INFORMATION (Score: 3.7)
CVSS3
Base Score: 3.7
Complexity: HIGH
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L
IMPACT SCORE
1.4
EXPLOITABILITY
2.2