Comparison Overview
GHD Québec

GHD Québec
4600, boulevard de la Côte-Vertu, Montréal, H4S 1C7, CA
Last Update: 28/02/2026
Nous sommes engagés à répondre aux plus grands enjeux mondiaux reliés à l’eau, à l’énergie et aux communautés. GHD est un réseau mondial de professionnels multidisciplinaires qui fournit aux clients des solutions intégrées grâce à son expertise en ingénierie, en enviro...

Tetra Tech
3475 East Foothill Blvd., Pasadena, 91107, US
Last Update: 01/04/2026
Tetra Tech is the leader in water, environment, and sustainable infrastructure, providing high-end consulting and engineering services for projects worldwide. With 25,000 employees working together, Tetra Tech provides clear solutions to complex problems by Leading with...
Compliance Ranges Comparison

GHD Québec







Tetra Tech






Benchmark & Cyber Underwriting Signals
Incidents vs Civil Engineering Industry Avg (This Year)
No incidents recorded for GHD Québec in 2026.
Incidents vs Civil Engineering Industry Avg (This Year)
No incidents recorded for Tetra Tech in 2026.
Incident History - GHD Québec (X = Date, Y = Severity)
GHD Québec cyber incidents detection timeline including parent company and subsidiaries.
Incident History - Tetra Tech (X = Date, Y = Severity)
Tetra Tech cyber incidents detection timeline including parent company and subsidiaries.
Notable Incidents

GHD Québec

Tetra Tech
FAQ
Latest Global CVEs
A flaw has been found in Comfast CF-WR631AX V3 up to 2.7.0.8. This issue affects the function system of the file /cgi-bin/mbox-config?section=ping_config of the component API Endpoint. This manipulation of the argument destination causes os command injection. The attack is possible to be carried out remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was detected in activepieces up to 0.83.0. This vulnerability affects the function handleUrlFile in the library packages/server/engine/src/lib/variables/processors/file.ts of the component File URL Handler. The manipulation results in server-side request forgery. The attack can be executed remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A security vulnerability has been detected in Radware Cyber Controller up to 10.11.0. This affects an unknown part of the component HTML Report Generation. The manipulation leads to HTML injection. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A weakness has been identified in kortix-ai suna up to 0.8.38. Affected by this issue is the function router.replace/router.push of the file apps/frontend/src/app/auth/page.tsx of the component Auth Endpoint. Executing a manipulation of the argument returnURL can lead to cross site scripting. The attack may be launched remotely. The exploit has been made available to the public and could be used for attacks. Upgrading to version 0.8.39 can resolve this issue. This patch is called f5dec7aa0c1b8fa0125938f292c0f2430ca75f6c. It is advisable to upgrade the affected component. The researcher explains: "The issue was fixed in v0.8.39 without notifying the wider user base via a security disclosure."
- https://gist.github.com/TrebledJ/fe7241910ac0aaeff86243fc88e9ffed
- https://github.com/kortix-ai/suna/
- https://github.com/kortix-ai/suna/commit/f5dec7aa0c1b8fa0125938f292c0f2430ca75f6c
- https://github.com/kortix-ai/suna/releases/tag/v0.8.39
- https://vuldb.com/cve/CVE-2026-12811
- https://vuldb.com/submit/837175
- https://vuldb.com/vuln/372605
- https://vuldb.com/vuln/372605/cti
A security flaw has been discovered in Edimax BR-6478AC V2 1.23. Affected by this vulnerability is the function mp of the file /goform/mp of the component POST Request Handler. Performing a manipulation of the argument command results in command injection. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.