Rankiteo Logo
Rankiteo
Leader in Cyber Underwriting
Loading...
NEWRankiteo Cyber Underwriting Desktop - Score, price, and bind from your desktop
WindowsmacOSLinux
Download

Comparison Overview

EcoWater Systems ItaliaEcoWater Systems Italia
VS
International Brotherhood of Electrical Workers (IBEW)International Brotherhood of Electrical Workers (IBEW)
EcoWater Systems Italia

EcoWater Systems Italia

Viale Famagosta, 75, Milan, 20142, IT

Last Update: 05/12/2025

View Profile
749/1000Moderate

EcoWater Systems, azienda leader nel settore del trattamento acqua residenziale, dal 1925 produce direttamente il 95% delle componenti dei propri prodotti, assicurando efficienza e qualità. EcoWater Systems si appoggia ad una rete di concessionari e partner, specializza...

NAICS:23
NAICS Definition:Construction
Employees:7
Subsidiaries:74
12-month incidents
0
Known data breaches
0
Attack type number
0
International Brotherhood of Electrical Workers (IBEW)

International Brotherhood of Electrical Workers (IBEW)

900 7th Street, NW, Washington, 20001, US

Last Update: 02/04/2026

View Profile
Between 700 and 749
http://www.ibew.org
727/1000Moderate

The IBEW represents 860,000 active. and retired who work in a wide variety of fields, including utilities, construction, telecommunications, broadcasting, manufacturing, railroads and government. The IBEW has members in both the United States and Canada and stands out ...

NAICS:23
NAICS Definition:Construction
Employees:13,005
Subsidiaries:0
12-month incidents
0
Known data breaches
2
Attack type number
1

Compliance Ranges Comparison

Based On Specific Ai Models Category
EcoWater Systems Italia

EcoWater Systems Italia

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA
International Brotherhood of Electrical Workers (IBEW)

International Brotherhood of Electrical Workers (IBEW)

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA

Benchmark & Cyber Underwriting Signals

Incidents vs Construction Industry Avg (This Year)

No incidents recorded for EcoWater Systems Italia in 2026.

Incidents

Incidents vs Construction Industry Avg (This Year)

No incidents recorded for International Brotherhood of Electrical Workers (IBEW) in 2026.

Incidents

Incident History - EcoWater Systems Italia (X = Date, Y = Severity)

EcoWater Systems Italia cyber incidents detection timeline including parent company and subsidiaries.

No timeline data available
R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Incident History - International Brotherhood of Electrical Workers (IBEW) (X = Date, Y = Severity)

International Brotherhood of Electrical Workers (IBEW) cyber incidents detection timeline including parent company and subsidiaries.

R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Notable Incidents

Last Cyber / HR Incidents / Global...
EcoWater Systems Italia

EcoWater Systems Italia

Incidents
No explicit notable incidents reported.
International Brotherhood of Electrical Workers (IBEW)

International Brotherhood of Electrical Workers (IBEW)

Incidents
🔒 Incident : Breach
IBE3502335110725
🔒 Incident : Breach
IBE827072925

FAQ

Between EcoWater Systems Italia company and International Brotherhood of Electrical Workers (IBEW) company, which one has the best AI Cybersecurity Score ?
Between EcoWater Systems Italia company and International Brotherhood of Electrical Workers (IBEW) company, which one has experienced more cyber incidents in the past ?
Between EcoWater Systems Italia company and International Brotherhood of Electrical Workers (IBEW) company, which one has experienced more cyber incidents this year ?
Between EcoWater Systems Italia company and International Brotherhood of Electrical Workers (IBEW) company, which one has experienced at least one ransomware attack ?
Between EcoWater Systems Italia company and International Brotherhood of Electrical Workers (IBEW) company, which one has experienced at least one data breach ?
Between EcoWater Systems Italia company and International Brotherhood of Electrical Workers (IBEW) company, which one has experienced at least one targeted cyberattack ?
Between EcoWater Systems Italia company and International Brotherhood of Electrical Workers (IBEW) company, which one has experienced at least one vulnerability ?
Between EcoWater Systems Italia company and International Brotherhood of Electrical Workers (IBEW) company, which one holds the most compliance certifications ?
Between EcoWater Systems Italia company and International Brotherhood of Electrical Workers (IBEW) company, which one holds the fewest compliance certifications ?
Between EcoWater Systems Italia company and International Brotherhood of Electrical Workers (IBEW) company, which one has the most subsidiaries ?
Between EcoWater Systems Italia company and International Brotherhood of Electrical Workers (IBEW) company, which one has the largest number of employees ?
Between EcoWater Systems Italia and International Brotherhood of Electrical Workers (IBEW), which company holds both SOC 2 Type 1 certifications ?
Between EcoWater Systems Italia and International Brotherhood of Electrical Workers (IBEW), which company holds both SOC 2 Type 2 certifications ?
Which company is ISO 27001 certified - EcoWater Systems Italia or International Brotherhood of Electrical Workers (IBEW) ?
Which company is PCI DSS compliant - EcoWater Systems Italia or International Brotherhood of Electrical Workers (IBEW) ?
Between EcoWater Systems Italia and International Brotherhood of Electrical Workers (IBEW), which company complies with HIPAA regulations for healthcare data ?
Between EcoWater Systems Italia and International Brotherhood of Electrical Workers (IBEW), which company complies with GDPR requirements ?

Latest Global CVEs

CVE-2026-48777
SUMMARY

FileBrowser Quantum is a free, self-hosted, web-based file manager. Versions prior to 1.3.2-stable, 1.4.0-beta and 1.4.1-beta are vulnerable to Path Traversal through the publicPatchHandler in backend/http/public.go which joins user-controlled fromPath and toPath body fields with the trusted d.share.Path BEFORE the downstream sanitizer runs. Because filepath.Join collapses .. segments during the join, the sanitizer in resourcePatchHandler never sees the traversal and the move/copy/rename operates on a path outside the shared directory. The same root-cause pattern was patched for the bulk DELETE endpoint as CVE-2026-44542 (GHSA-fwj3-42wh-8673), but the PATCH handler with the identical pattern was not updated. A public share link with AllowModify=true is sufficient to exploit this. Anyone holding such a link can move, copy, or rename arbitrary files within the share owner's source root. This issue has been fixed in versions 1.3.3-stable and 1.4.2-beta.

PUBLISHED
Date2026-06-16
UPDATED
Date2026-06-16
RISK INFORMATION (Score: )
CVSS4
Base Score: 9.3
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
NA
EXPLOITABILITY
NA
CVE-2026-47750
SUMMARY

stable-diffusion.cpp is a pure C/C++ library for running diffusion model (Stable Diffusion, Flux, Wan, Qwen Image, Z-Image, and more) inference. In versions prior to master-584-0a7ae07, the pickle .ckpt parser in src/model.cpp contained a heap buffer overflow vulnerability in the GLOBAL opcode handler. The issue was caused by missing validation when searching for newline-delimited fields. A crafted .ckpt file without the expected newline could cause the parser to use -1 as a copy length, resulting in immediate heap corruption. The attack requires the victim or application to load a .ckpt file from an untrusted source, such as a downloaded model from a model sharing site. The issue has been resolved in version master-584-0a7ae07. If developers are unable to immediately update their applications they can work around this issue by following these instructions: do not load .ckpt checkpoint files from untrusted sources, and prefer trusted model sources and safer formats such as .safetensors where possible.

PUBLISHED
Date2026-06-16
UPDATED
Date2026-06-16
RISK INFORMATION (Score: 7.8)
CVSS3
Base Score: 7.8
Complexity: LOW
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
IMPACT SCORE
5.9
EXPLOITABILITY
1.8
CVE-2026-47747
SUMMARY

stable-diffusion.cpp is a pure C/C++ library for running diffusion model (Stable Diffusion, Flux, Wan, Qwen Image, Z-Image, and more) inference. In versions prior to master-584-0a7ae07, the pickle .ckpt parser in src/model.cpp contained a heap buffer overflow vulnerability in the BINUNICODE opcode handler. The issue was caused by sign confusion on the opcode length field. A crafted .ckpt file could trigger memcpy with a very large length derived from a negative signed value, causing immediate heap corruption. The issue has been resolved in version master-584-0a7ae07. If developers are unable to immediately update their applications they can work around this issue by only loading .ckpt checkpoint files from trusted sources and preferring trusted model sources and safer formats such as .safetensors where possible.

PUBLISHED
Date2026-06-16
UPDATED
Date2026-06-16
RISK INFORMATION (Score: 7.8)
CVSS3
Base Score: 7.8
Complexity: LOW
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
IMPACT SCORE
5.9
EXPLOITABILITY
1.8
CVE-2026-46448
SUMMARY

In OpenStack Nova before 33.0.2, the server create API does not strip certain hint data. The resulting instance has no Placement allocation.

PUBLISHED
Date2026-06-16
UPDATED
Date2026-06-16
RISK INFORMATION (Score: 5.4)
CVSS3
Base Score: 5.4
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:L
IMPACT SCORE
2.5
EXPLOITABILITY
2.8
CVE-2026-22313
SUMMARY

The device has a webserver that exposes a REST API authenticated with a token on the management network. By exploiting an OS command injection vulnerability an authenticated attacker can send arbitrary commands to the device that are executed with administrative permissions by the underlying operating system.

PUBLISHED
Date2026-06-16
UPDATED
Date2026-06-16
RISK INFORMATION (Score: 9.1)
CVSS3
Base Score: 9.1
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
IMPACT SCORE
6
EXPLOITABILITY
2.3