Rankiteo Logo
Rankiteo
Leader in Cyber Underwriting
Loading...
NEWRankiteo Cyber Underwriting Desktop - Score, price, and bind from your desktop
WindowsmacOSLinux
Download

Comparison Overview

B. Braun GroupB. Braun Group
VS
Olympus CorporationOlympus Corporation
B. Braun Group

B. Braun Group

Carl-Braun-Straße 1, Melsungen, DE, 34212

Last Update: 01/04/2026

View Profile
Between 800 and 849
https://www.bbraun.com
801/1000Good

As a leading medical technology company, B. Braun protects and improves the health of people around the world. For more than 185 years, the family-owned company has been accelerating progress in health care with pioneering spirit and groundbreaking contributions. This i...

NAICS:3391
NAICS Definition:Medical Equipment and Supplies Manufacturing
Employees:28,661
Subsidiaries:5
12-month incidents
0
Known data breaches
0
Attack type number
0
Olympus Corporation

Olympus Corporation

Nishi-shinjuku 2-3-1 Shinjuku Monolith, Shinjuku-ku, JP

Last Update: 01/04/2026

View Profile
791/1000Fair

Olympus is passionate about creating customer-driven solutions for the medical industry. For more than 100 years, Olympus has focused on making people’s lives healthier, safer and more fulfilling by helping detect, prevent, and treat disease, furthering scientific resea...

NAICS:3391
NAICS Definition:Medical Equipment and Supplies Manufacturing
Employees:13,565
Subsidiaries:0
12-month incidents
0
Known data breaches
0
Attack type number
0

Compliance Ranges Comparison

Based On Specific Ai Models Category
B. Braun Group

B. Braun Group

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA
Olympus Corporation

Olympus Corporation

-
ISO 27001Not verified
ISO 27001
-
SOC2 Type 1Not verified
SOC2 Type 1
-
SOC2 Type 2Not verified
SOC2 Type 2
-
GDPRNot verified
GDPR
-
PCI DSSNot verified
PCI DSS
-
HIPAANot verified
HIPAA

Benchmark & Cyber Underwriting Signals

Incidents vs Medical Equipment Manufacturing Industry Avg (This Year)

No incidents recorded for B. Braun Group in 2026.

Incidents

Incidents vs Medical Equipment Manufacturing Industry Avg (This Year)

No incidents recorded for Olympus Corporation in 2026.

Incidents

Incident History - B. Braun Group (X = Date, Y = Severity)

B. Braun Group cyber incidents detection timeline including parent company and subsidiaries.

No timeline data available
R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Incident History - Olympus Corporation (X = Date, Y = Severity)

Olympus Corporation cyber incidents detection timeline including parent company and subsidiaries.

No timeline data available
R - Ransomware
C - Cyber Attack
D - Data Breach
V - Vulnerability

Notable Incidents

Last Cyber / HR Incidents / Global...
B. Braun Group

B. Braun Group

Incidents
No explicit notable incidents reported.
Olympus Corporation

Olympus Corporation

Incidents
No explicit notable incidents reported.

FAQ

Between B. Braun Group company and Olympus Corporation company, which one has the best AI Cybersecurity Score ?
Between B. Braun Group company and Olympus Corporation company, which one has experienced more cyber incidents in the past ?
Between B. Braun Group company and Olympus Corporation company, which one has experienced more cyber incidents this year ?
Between B. Braun Group company and Olympus Corporation company, which one has experienced at least one ransomware attack ?
Between B. Braun Group company and Olympus Corporation company, which one has experienced at least one data breach ?
Between B. Braun Group company and Olympus Corporation company, which one has experienced at least one targeted cyberattack ?
Between B. Braun Group company and Olympus Corporation company, which one has experienced at least one vulnerability ?
Between B. Braun Group company and Olympus Corporation company, which one holds the most compliance certifications ?
Between B. Braun Group company and Olympus Corporation company, which one holds the fewest compliance certifications ?
Between B. Braun Group company and Olympus Corporation company, which one has the most subsidiaries ?
Between B. Braun Group company and Olympus Corporation company, which one has the largest number of employees ?
Between B. Braun Group and Olympus Corporation, which company holds both SOC 2 Type 1 certifications ?
Between B. Braun Group and Olympus Corporation, which company holds both SOC 2 Type 2 certifications ?
Which company is ISO 27001 certified - B. Braun Group or Olympus Corporation ?
Which company is PCI DSS compliant - B. Braun Group or Olympus Corporation ?
Between B. Braun Group and Olympus Corporation, which company complies with HIPAA regulations for healthcare data ?
Between B. Braun Group and Olympus Corporation, which company complies with GDPR requirements ?

Latest Global CVEs

CVE-2026-12814
SUMMARY

A flaw has been found in Comfast CF-WR631AX V3 up to 2.7.0.8. This issue affects the function system of the file /cgi-bin/mbox-config?section=ping_config of the component API Endpoint. This manipulation of the argument destination causes os command injection. The attack is possible to be carried out remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

PUBLISHED
Date2026-06-21
UPDATED
Date2026-06-21
RISK INFORMATION (Score: 6.3)
CVSS2
Base Score: 6.5
Complexity: LOW
AV:N/AC:L/Au:S/C:P/I:P/A:P
CVSS3
Base Score: 6.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CVSS4
Base Score: 2.1
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
3.4
EXPLOITABILITY
2.8
CVE-2026-12813
SUMMARY

A vulnerability was detected in activepieces up to 0.83.0. This vulnerability affects the function handleUrlFile in the library packages/server/engine/src/lib/variables/processors/file.ts of the component File URL Handler. The manipulation results in server-side request forgery. The attack can be executed remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

PUBLISHED
Date2026-06-21
UPDATED
Date2026-06-21
RISK INFORMATION (Score: 6.3)
CVSS2
Base Score: 6.5
Complexity: LOW
AV:N/AC:L/Au:S/C:P/I:P/A:P
CVSS3
Base Score: 6.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CVSS4
Base Score: 2.1
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
3.4
EXPLOITABILITY
2.8
CVE-2026-12812
SUMMARY

A security vulnerability has been detected in Radware Cyber Controller up to 10.11.0. This affects an unknown part of the component HTML Report Generation. The manipulation leads to HTML injection. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

PUBLISHED
Date2026-06-21
UPDATED
Date2026-06-21
RISK INFORMATION (Score: 3.5)
CVSS2
Base Score: 4.0
Complexity: LOW
AV:N/AC:L/Au:S/C:N/I:P/A:N
CVSS3
Base Score: 3.5
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N
CVSS4
Base Score: 2.0
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
1.4
EXPLOITABILITY
2.1
CVE-2026-12811
SUMMARY

A weakness has been identified in kortix-ai suna up to 0.8.38. Affected by this issue is the function router.replace/router.push of the file apps/frontend/src/app/auth/page.tsx of the component Auth Endpoint. Executing a manipulation of the argument returnURL can lead to cross site scripting. The attack may be launched remotely. The exploit has been made available to the public and could be used for attacks. Upgrading to version 0.8.39 can resolve this issue. This patch is called f5dec7aa0c1b8fa0125938f292c0f2430ca75f6c. It is advisable to upgrade the affected component. The researcher explains: "The issue was fixed in v0.8.39 without notifying the wider user base via a security disclosure."

PUBLISHED
Date2026-06-21
UPDATED
Date2026-06-21
RISK INFORMATION (Score: 4.3)
CVSS2
Base Score: 5.0
Complexity: LOW
AV:N/AC:L/Au:N/C:N/I:P/A:N
CVSS3
Base Score: 4.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N
CVSS4
Base Score: 2.1
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
1.4
EXPLOITABILITY
2.8
CVE-2026-12810
SUMMARY

A security flaw has been discovered in Edimax BR-6478AC V2 1.23. Affected by this vulnerability is the function mp of the file /goform/mp of the component POST Request Handler. Performing a manipulation of the argument command results in command injection. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.

PUBLISHED
Date2026-06-21
UPDATED
Date2026-06-21
RISK INFORMATION (Score: 6.3)
CVSS2
Base Score: 6.5
Complexity: LOW
AV:N/AC:L/Au:S/C:P/I:P/A:P
CVSS3
Base Score: 6.3
Complexity: LOW
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CVSS4
Base Score: 2.1
Complexity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
IMPACT SCORE
3.4
EXPLOITABILITY
2.8