Comparison Overview

The Cigna Group

VS

Atrium Health

The Cigna Group

900 Cottage Grove Rd, Bloomfield, Connecticut, US, 06002
Last Update: 2025-11-27

The Cigna Group is a global health company committed to creating a better future built on the vitality of every individual and every community. We relentlessly challenge ourselves to partner and innovate solutions for better health. The Cigna Group includes products and services marketed under Cigna Healthcare, Evernorth Health Services or its subsidiaries. The Cigna Group maintains sales capabilities in more than 30 countries and jurisdictions, and has more than 190 million customer relationships around the world.

NAICS: 62
NAICS Definition: Health Care and Social Assistance
Employees: 4,402
Subsidiaries: 0
12-month incidents
0
Known data breaches
1
Attack type number
1

Atrium Health

1000 Blythe Blvd, Charlotte, North Carolina, US, 28203
Last Update: 2025-11-30
Between 750 and 799

Atrium Health, part of Advocate Health, is redefining how, when and where care is delivered. We are rethinking methods of care delivery to reach more people and bringing human kindness to every step of their health journey. Our dedication to elevating health care for every individual, every teammate and every community is unwavering. We won't stop until everyone – no matter who they are or where they come from – has the possibility to live well. And because of this, we are redefining why we exist, our purpose as an organization and how we make it happen together as one.

NAICS: 62
NAICS Definition: Health Care and Social Assistance
Employees: 29,437
Subsidiaries: 0
12-month incidents
0
Known data breaches
0
Attack type number
0

Compliance Badges Comparison

Security & Compliance Standards Overview

https://images.rankiteo.com/companyimages/the-cigna-group.jpeg
The Cigna Group
ISO 27001
ISO 27001 certification not verified
Not verified
SOC2 Type 1
SOC2 Type 1 certification not verified
Not verified
SOC2 Type 2
SOC2 Type 2 certification not verified
Not verified
GDPR
GDPR certification not verified
Not verified
PCI DSS
PCI DSS certification not verified
Not verified
HIPAA
HIPAA certification not verified
Not verified
https://images.rankiteo.com/companyimages/atrium-health-us.jpeg
Atrium Health
ISO 27001
ISO 27001 certification not verified
Not verified
SOC2 Type 1
SOC2 Type 1 certification not verified
Not verified
SOC2 Type 2
SOC2 Type 2 certification not verified
Not verified
GDPR
GDPR certification not verified
Not verified
PCI DSS
PCI DSS certification not verified
Not verified
HIPAA
HIPAA certification not verified
Not verified
Compliance Summary
The Cigna Group
100%
Compliance Rate
0/4 Standards Verified
Atrium Health
0%
Compliance Rate
0/4 Standards Verified

Benchmark & Cyber Underwriting Signals

Incidents vs Hospitals and Health Care Industry Average (This Year)

No incidents recorded for The Cigna Group in 2025.

Incidents vs Hospitals and Health Care Industry Average (This Year)

No incidents recorded for Atrium Health in 2025.

Incident History — The Cigna Group (X = Date, Y = Severity)

The Cigna Group cyber incidents detection timeline including parent company and subsidiaries

Incident History — Atrium Health (X = Date, Y = Severity)

Atrium Health cyber incidents detection timeline including parent company and subsidiaries

Notable Incidents

Last 3 Security & Risk Events by Company

https://images.rankiteo.com/companyimages/the-cigna-group.jpeg
The Cigna Group
Incidents

Date Detected: 3/2012
Type:Breach
Attack Vector: Email
Blog: Blog
https://images.rankiteo.com/companyimages/atrium-health-us.jpeg
Atrium Health
Incidents

No Incident

FAQ

Atrium Health company demonstrates a stronger AI Cybersecurity Score compared to The Cigna Group company, reflecting its advanced cybersecurity posture governance and monitoring frameworks.

The Cigna Group company has historically faced a number of disclosed cyber incidents, whereas Atrium Health company has not reported any.

In the current year, Atrium Health company and The Cigna Group company have not reported any cyber incidents.

Neither Atrium Health company nor The Cigna Group company has reported experiencing a ransomware attack publicly.

The Cigna Group company has disclosed at least one data breach, while the other Atrium Health company has not reported such incidents publicly.

Neither Atrium Health company nor The Cigna Group company has reported experiencing targeted cyberattacks publicly.

Neither The Cigna Group company nor Atrium Health company has reported experiencing or disclosing vulnerabilities publicly.

Neither The Cigna Group nor Atrium Health holds any compliance certifications.

Neither company holds any compliance certifications.

Neither The Cigna Group company nor Atrium Health company has publicly disclosed detailed information about the number of their subsidiaries.

Atrium Health company employs more people globally than The Cigna Group company, reflecting its scale as a Hospitals and Health Care.

Neither The Cigna Group nor Atrium Health holds SOC 2 Type 1 certification.

Neither The Cigna Group nor Atrium Health holds SOC 2 Type 2 certification.

Neither The Cigna Group nor Atrium Health holds ISO 27001 certification.

Neither The Cigna Group nor Atrium Health holds PCI DSS certification.

Neither The Cigna Group nor Atrium Health holds HIPAA certification.

Neither The Cigna Group nor Atrium Health holds GDPR certification.

Latest Global CVEs (Not Company-Specific)

Description

A vulnerability was determined in motogadget mo.lock Ignition Lock up to 20251125. Affected by this vulnerability is an unknown functionality of the component NFC Handler. Executing manipulation can lead to use of hard-coded cryptographic key . The physical device can be targeted for the attack. A high complexity level is associated with this attack. The exploitation appears to be difficult. The vendor was contacted early about this disclosure but did not respond in any way.

Risk Information
cvss2
Base: 1.2
Severity: HIGH
AV:L/AC:H/Au:N/C:P/I:N/A:N
cvss3
Base: 2.0
Severity: HIGH
CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N
cvss4
Base: 1.0
Severity: HIGH
CVSS:4.0/AV:P/AC:H/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Description

OrangeHRM is a comprehensive human resource management (HRM) system. From version 5.0 to 5.7, the interview attachment retrieval endpoint in the Recruitment module serves files based solely on an authenticated session and user-supplied identifiers, without verifying whether the requester has permission to access the associated interview record. Because the server does not perform any recruitment-level authorization checks, an ESS-level user with no access to recruitment workflows can directly request interview attachment URLs and receive the corresponding files. This exposes confidential interview documents—including candidate CVs, evaluations, and supporting files—to unauthorized users. The issue arises from relying on predictable object identifiers and session presence rather than validating the user’s association with the relevant recruitment process. This issue has been patched in version 5.8.

Risk Information
cvss4
Base: 5.3
Severity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Description

OrangeHRM is a comprehensive human resource management (HRM) system. From version 5.0 to 5.7, the application’s recruitment attachment retrieval endpoint does not enforce the required authorization checks before serving candidate files. Even users restricted to ESS-level access, who have no permission to view the Recruitment module, can directly access candidate attachment URLs. When an authenticated request is made to the attachment endpoint, the system validates the session but does not confirm that the requesting user has the necessary recruitment permissions. As a result, any authenticated user can download CVs and other uploaded documents for arbitrary candidates by issuing direct requests to the attachment endpoint, leading to unauthorized exposure of sensitive applicant data. This issue has been patched in version 5.8.

Risk Information
cvss4
Base: 5.3
Severity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Description

OrangeHRM is a comprehensive human resource management (HRM) system. From version 5.0 to 5.7, the application does not invalidate existing sessions when a user is disabled or when a password change occurs, allowing active session cookies to remain valid indefinitely. As a result, a disabled user, or an attacker using a compromised account, can continue to access protected pages and perform operations as long as a prior session remains active. Because the server performs no session revocation or session-store cleanup during these critical state changes, disabling an account or updating credentials has no effect on already-established sessions. This makes administrative disable actions ineffective and allows unauthorized users to retain full access even after an account is closed or a password is reset, exposing the system to prolonged unauthorized use and significantly increasing the impact of account takeover scenarios. This issue has been patched in version 5.8.

Risk Information
cvss4
Base: 8.7
Severity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Description

OrangeHRM is a comprehensive human resource management (HRM) system. From version 5.0 to 5.7, the password reset workflow does not enforce that the username submitted in the final reset request matches the account for which the reset process was originally initiated. After obtaining a valid reset link for any account they can receive email for, an attacker can alter the username parameter in the final reset request to target a different user. Because the system accepts the supplied username without verification, the attacker can set a new password for any chosen account, including privileged accounts, resulting in full account takeover. This issue has been patched in version 5.8.

Risk Information
cvss4
Base: 8.7
Severity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X