Comparison Overview

Johnson & Johnson

VS

Henry Ford Health

Johnson & Johnson

New Brunswick, NJ, US, 08903
Last Update: 2025-12-09
Between 750 and 799

At Johnson & Johnson, we believe health is everything. As a focused healthcare company, with expertise in Innovative Medicine and MedTech, we’re empowered to tackle the world’s toughest health challenges, innovate through science and technology, and transform patient care. ​ All of this is possible because of our people. We’re passionate innovators who put people first, and through our purpose-driven culture and talented workforce, we are stronger than ever. ​ Learn more at https://www.jnj.com. Community Guidelines: http://www.jnj.com/social-media-community-guidelines

NAICS: 62
NAICS Definition: Health Care and Social Assistance
Employees: 108,305
Subsidiaries: 8
12-month incidents
1
Known data breaches
4
Attack type number
1

Henry Ford Health

1 Ford Place, Detroit, MI, US, 48202
Last Update: 2025-12-09
Between 750 and 799

*Job seekers: please be aware of fraudulent job postings and phishing scams via LinkedIn. Henry Ford Health only contacts applicants through our human resources department and via a corporate email address. Here are some tips to be aware of: http://ow.ly/Kc0o50EKory Serving communities across Michigan and beyond, Henry Ford Health is committed to partnering with patients & members along their entire health journey. Henry Ford Health provides a full continuum of services – from primary and preventative care, to complex and specialty care, health insurance, a full suite of home health offerings, virtual care, pharmacy, eye care & other healthcare retail. It is one of the nation’s leading academic medical centers, recognized for clinical excellence in cancer care, cardiology and cardiovascular surgery, neurology and neurosurgery, orthopedics and sports medicine, and multi-organ transplants. Consistently ranked among the top five NIH-funded institutions in Michigan, Henry Ford Health engages in thousands of research projects annually. Equally committed to educating the next generation of health professionals, Henry Ford Health trains more than 4,000 medical students, residents and fellows every year across 50+ accredited programs. With more than 50,000 valued team members, Henry Ford Health is also among Michigan’s largest and most diverse employers. President and CEO Bob Riney leads the health system and serves a growing number of customers across more than 550 sites across Michigan. That includes: 13 acute care hospitals; 3 behavioral health facilities including two world-class addiction treatment centers; a state-of-the-art orthopedics and sports medicine facility; multiple cancer care destinations including the Brigitte Harris Cancer Pavilion, Henry Ford Health’s premier location in Detroit; & more options than ever for primary care for patients and families across the region.

NAICS: 62
NAICS Definition: Health Care and Social Assistance
Employees: 20,343
Subsidiaries: 0
12-month incidents
0
Known data breaches
0
Attack type number
1

Compliance Badges Comparison

Security & Compliance Standards Overview

https://images.rankiteo.com/companyimages/johnson-&-johnson.jpeg
Johnson & Johnson
ISO 27001
ISO 27001 certification not verified
Not verified
SOC2 Type 1
SOC2 Type 1 certification not verified
Not verified
SOC2 Type 2
SOC2 Type 2 certification not verified
Not verified
GDPR
GDPR certification not verified
Not verified
PCI DSS
PCI DSS certification not verified
Not verified
HIPAA
HIPAA certification not verified
Not verified
https://images.rankiteo.com/companyimages/henry-ford-health.jpeg
Henry Ford Health
ISO 27001
ISO 27001 certification not verified
Not verified
SOC2 Type 1
SOC2 Type 1 certification not verified
Not verified
SOC2 Type 2
SOC2 Type 2 certification not verified
Not verified
GDPR
GDPR certification not verified
Not verified
PCI DSS
PCI DSS certification not verified
Not verified
HIPAA
HIPAA certification not verified
Not verified
Compliance Summary
Johnson & Johnson
100%
Compliance Rate
0/4 Standards Verified
Henry Ford Health
0%
Compliance Rate
0/4 Standards Verified

Benchmark & Cyber Underwriting Signals

Incidents vs Hospitals and Health Care Industry Average (This Year)

Johnson & Johnson has 20.48% more incidents than the average of same-industry companies with at least one recorded incident.

Incidents vs Hospitals and Health Care Industry Average (This Year)

No incidents recorded for Henry Ford Health in 2025.

Incident History — Johnson & Johnson (X = Date, Y = Severity)

Johnson & Johnson cyber incidents detection timeline including parent company and subsidiaries

Incident History — Henry Ford Health (X = Date, Y = Severity)

Henry Ford Health cyber incidents detection timeline including parent company and subsidiaries

Notable Incidents

Last 3 Security & Risk Events by Company

https://images.rankiteo.com/companyimages/johnson-&-johnson.jpeg
Johnson & Johnson
Incidents

Date Detected: 7/2025
Type:Breach
Motivation: Financial Gain
Blog: Blog

Date Detected: 8/2024
Type:Breach
Attack Vector: Hacking
Blog: Blog

Date Detected: 6/2023
Type:Breach
Motivation: Financial Gain (Plaintiffs), Corporate Accountability, Consumer Protection
Blog: Blog
https://images.rankiteo.com/companyimages/henry-ford-health.jpeg
Henry Ford Health
Incidents

Date Detected: 12/2017
Type:Data Leak
Blog: Blog

Date Detected: 02/2011
Type:Data Leak
Attack Vector: Physical Loss
Motivation: Accidental
Blog: Blog

FAQ

Johnson & Johnson company demonstrates a stronger AI Cybersecurity Score compared to Henry Ford Health company, reflecting its advanced cybersecurity posture governance and monitoring frameworks.

Johnson & Johnson company has faced a higher number of disclosed cyber incidents historically compared to Henry Ford Health company.

In the current year, Johnson & Johnson company has reported more cyber incidents than Henry Ford Health company.

Neither Henry Ford Health company nor Johnson & Johnson company has reported experiencing a ransomware attack publicly.

Johnson & Johnson company has disclosed at least one data breach, while the other Henry Ford Health company has not reported such incidents publicly.

Neither Henry Ford Health company nor Johnson & Johnson company has reported experiencing targeted cyberattacks publicly.

Neither Johnson & Johnson company nor Henry Ford Health company has reported experiencing or disclosing vulnerabilities publicly.

Neither Johnson & Johnson nor Henry Ford Health holds any compliance certifications.

Neither company holds any compliance certifications.

Johnson & Johnson company has more subsidiaries worldwide compared to Henry Ford Health company.

Johnson & Johnson company employs more people globally than Henry Ford Health company, reflecting its scale as a Hospitals and Health Care.

Neither Johnson & Johnson nor Henry Ford Health holds SOC 2 Type 1 certification.

Neither Johnson & Johnson nor Henry Ford Health holds SOC 2 Type 2 certification.

Neither Johnson & Johnson nor Henry Ford Health holds ISO 27001 certification.

Neither Johnson & Johnson nor Henry Ford Health holds PCI DSS certification.

Neither Johnson & Johnson nor Henry Ford Health holds HIPAA certification.

Neither Johnson & Johnson nor Henry Ford Health holds GDPR certification.

Latest Global CVEs (Not Company-Specific)

Description

NXLog Agent before 6.11 can load a file specified by the OPENSSL_CONF environment variable.

Risk Information
cvss3
Base: 8.1
Severity: HIGH
CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
Description

uriparser through 0.9.9 allows unbounded recursion and stack consumption, as demonstrated by ParseMustBeSegmentNzNc with large input containing many commas.

Risk Information
cvss3
Base: 2.9
Severity: HIGH
CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L
Description

A vulnerability was detected in Mayan EDMS up to 4.10.1. The affected element is an unknown function of the file /authentication/. The manipulation results in cross site scripting. The attack may be performed from remote. The exploit is now public and may be used. Upgrading to version 4.10.2 is sufficient to fix this issue. You should upgrade the affected component. The vendor confirms that this is "[f]ixed in version 4.10.2". Furthermore, that "[b]ackports for older versions in process and will be out as soon as their respective CI pipelines complete."

Risk Information
cvss2
Base: 5.0
Severity: LOW
AV:N/AC:L/Au:N/C:N/I:P/A:N
cvss3
Base: 4.3
Severity: LOW
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N
cvss4
Base: 5.3
Severity: LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Description

MJML through 4.18.0 allows mj-include directory traversal to test file existence and (in the type="css" case) read files. NOTE: this issue exists because of an incomplete fix for CVE-2020-12827.

Risk Information
cvss3
Base: 4.5
Severity: HIGH
CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:L/I:N/A:L
Description

A half-blind Server Side Request Forgery (SSRF) vulnerability exists in kube-controller-manager when using the in-tree Portworx StorageClass. This vulnerability allows authorized users to leak arbitrary information from unprotected endpoints in the control plane’s host network (including link-local or loopback services).

Risk Information
cvss3
Base: 5.8
Severity: HIGH
CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:N/A:N